The canal fill ratio as a factor influencing the aseptic loosening of the Müller-type cemented stem--preliminary report.

نویسندگان

  • Gordan Gulan
  • Hari Jurdana
چکیده

The Müller type cemented hip prosthesis, also called self-locking prosthesis, is one of the most extensively copied and utilized hip prostheses. Considering the implantation of the cemented stem, the author originally suggested achieving a press fit between the stem and endostal cortex by implanting a prosthesis of the largest possible size. Analyzing our group of patients who undergo aseptic stem revision, we try to quantify the term "press fit" by measuring the filling of the femoral canal by the metal stem, the so-called canal-fill ratio. Our preliminary results suggest that press-fit is achieved when the stem occupies more than 90% of the canal diameter in the anterior-posterior projection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk factors for aseptic loosening of Müller-type straight stems

Background and purpose Even small differences in design variables for the femoral stem may influence the outcome of a hip arthroplasty. We performed a risk factor analysis for aseptic loosening of 4 different versions of cemented Müller-type straight stems with special emphasis on design modifications (2 shapes, MSS or SL, and 2 materials, CoNiCrMo (Co) or Ti-6Al-7Nb (Ti)). Methods We investiga...

متن کامل

Similar effect of stem geometry on radiological changes with 2 types of cemented straight stem

BACKGROUND AND PURPOSE There are 2 basic principles in cemented stem fixation: shape-closed and force-closed. We investigated 2 shape-closed straight stems, the Müller (MSS) and the Virtec (VSS), which differ only in geometrical cross section, to determine whether the difference in stem shape would affect the radiological results or long-term survival. PATIENTS AND METHODS We included 711 hip...

متن کامل

Revision for aseptic stem loosening using the cemented Charnley prosthesis. A review of 351 hips.

We reviewed 351 cemented revisions of femoral stems performed for aseptic loosening. At a mean of six years after the revision operation 72.1% of the patients were pain-free and 21.4% had only mild or occasional discomfort. The latest radiographs showed definite stem loosening in 10 (2.8%) and 20 hips (5.7%) had required rerevision, only nine (2.6%) of which were for mechanical failure of the s...

متن کامل

Cemented versus cementless endoprostheses for lower limb salvage surgery.

PURPOSE To determine the survival and failures of cemented vs cementless endoprostheses. METHODS We retrospectively studied 232 patients treated with lower limb salvage surgery and reconstruction using cementless and cemented endoprostheses from 2002 to 2007. We compared survival and failures of the endoprostheses regarding age, gender, body mass index (BMI), diagnosis, site of reconstruction...

متن کامل

18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register

BACKGROUND AND PURPOSE Few studies have compared the long-term survival of cemented primary total hip arthroplasties (THAs), and several prostheses have been used without adequate knowledge of their endurance. We studied long-term outcome based on data in the Norwegian Arthroplasty Register. PATIENTS AND METHODS The 10 most used prosthesis brands in 62,305 primary Palacos or Simplex cemented ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Collegium antropologicum

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 2007