Clinical experience of two Israeli medical centers with the implantable loop recorder in patients with syncope: from diagnosis to treatment.

نویسندگان

  • Ehud Kadmon
  • Doron Menachemi
  • Jairo Kusniec
  • Moti Haim
  • Michael Geist
  • Boris Strasberg
چکیده

BACKGROUND The implantable loop recorder (ILR) is an important tool for the evaluation of unexplained syncope, particularly in cases of rarely occurring arrhythmia. OBJECTIVES To review the clinical experience of two Israeli medical centers with the ILR. METHODS We reviewed the medical records of patients with unexplained syncope evaluated with the ILR at Rabin Medical Center (2006-2010) and Wolfson Medical Center (2000-2009). RESULTS The study group included 75 patients (44 males) followed for 11.9 +/- 9.5 months after ILR implantation. Patients' mean age was 64 +/- 20 years. The ILR identified an arrhythmic mechanism of syncope in 20 patients (17 bradyarrhythmias, 3 tachyarrhythmias) and excluded arrhythmias in 12, for a diagnostic yield of 42.7%. It was not diagnostic in 17 patients (22.7%) at the time of explant; 26 patients (34.7%) were still in follow-up. In two patients ILR results that were initially negative were reversed by later ILR tracings. The patients with bradyarrhythmias included 9 of 16 (56.3%) with surface electrocardiogram conduction disturbances and 2 of 12 (16.7%) with negative findings on carotid sinus massage. All bradyarrhythmic patients received pacemakers; the seven patients for whom post-intervention data were available had no or mild symptoms. CONCLUSIONS The ILR has a high diagnostic yield. Pre-ILR findings correlating with the ILR results are conduction disturbances (positive predictor of arrhythmia) and negative carotid sinus massage results (negative predictor of arrhythmia). Proper patient instruction is necessary to obtain accurate results. Caution is advised when excluding an arrhythmia on the basis of ILR tracings, and long-term follow-up is warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Implantable Loop Recorder: Current Uses, Future Directions

Implantable loop recorders (ILRs) have evolved as an elegant means of establishing a correlation between symptoms and cardiac rhythm disturbances in patients suffering from recurrent and unexplained episodes of syncope. In this review, we focus on the currently available ILRs on the US market and our institution’s experience with a novel ILR implantation technique. We also review the currently ...

متن کامل

The implantable loop recorder-an important addition to the armentarium in the management of unexplained syncope.

INTRODUCTION Unexplained syncope is a common condition with a significant impact both on the patient and on healthcare expenditure. Often, the diagnosis is hampered due to the temporary sporadic nature of the symptoms. Conventional monitoring methods have a low yield for identifying an abnormality during a spontaneous event. The implantable loop recorder (ILR), often underutilised, is an import...

متن کامل

Effectiveness and safety of remote monitoring of patients with an implantable loop recorder.

INTRODUCTION AND OBJECTIVES Implantable loop recorders have proven efficacy in the study of patients with syncope and palpitations. Remote monitoring of patients with pacemakers and implantable cardioverter-defibrillators has been shown to be safe and effective. The purpose of this study was to analyze the safety and effectiveness of remote monitoring in patients with an implantable loop record...

متن کامل

Usefulness of an Implantable Loop Recorder in Patients with Syncope of an Unknown Cause

PURPOSE The mechanisms underlying syncope remain unknown in about 20% of patients with recurrent syncope. The implantable loop recorder (ILR) has been shown to be a useful diagnostic tool in patients with unexplained syncope even after negative initial evaluations. Nevertheless, ILR has rarely been used in clinical practice. MATERIALS AND METHODS This study included 18 consecutive patients wh...

متن کامل

Electromagnetic interference in an implantable loop recorder caused by a portable digital media player.

The implantable loop recorder has been shown to be a cost-effective tool for diagnosis of intermittent cardiovascular symptoms such as syncope and palpitations. Electromagnetic interference in these recorders may be caused by commonly encountered electronic devices such as antitheft electronic surveillance systems and magnetic resonance imaging cameras. In this report, we describe interference ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Israel Medical Association journal : IMAJ

دوره 14 8  شماره 

صفحات  -

تاریخ انتشار 2012