Clinical Outcomes of Posterior C1 and C2 Screw-Rod Fixation for Atlantoaxial Instability.

نویسندگان

  • Hasan Serdar Işik
  • Evren Sandal
  • Sedat Çağli
چکیده

AIM In this study, we aimed at sharing our experiences and contributing to the literature by making a retrospective analysis of the patients we operated with screw-rod system for atlantoaxial instability in our clinic. MATERIAL AND METHODS Archive files of adult patients, who were operated for posterior C1-C2 stabilization with screw and rod in our clinic between January 2006 and January 2016, were analyzed. 28 patients, who had pre and post-operative images, follow-up forms and who were followed for at least one year, were analyzed. Preoperative clinical and radiological records, preoperative observations, postoperative complications, and clinical responses were evaluated. RESULTS The average age of 28 patients (F:13 M:19) was 44.7 (21-73). Fixation was performed with C1-C2 screw-rod system on the basis of the following diagnoses; type 2 odontoid fracture (16), basilar invagination (5), C1-C2 instability (5), and atlantoaxial subluxation secondary to rheumatoid arthritis (2). Lateral mass screws were inserted at C1 segment. C2 screws inserted were bilateral pedicle in 12 cases, bilateral pars in 4, bilateral laminar in 8 and one side pars, one side laminar in 4 cases. There was no screw malposition. Neither implant failure nor recurrent instability was observed during follow-up. Significant clinical improvement was reported according to the assessments done with JOA and VAS scores. CONCLUSION C1-C2 screw fixation is regarded as a more successful and safe method than other fixation methods in surgical treatment of atlantoaxial instability considering complications, success in reduction, fusion and fixation strength. C2 laminar screw technique is as successful as the other alternatives in fixation and fusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior atlantal lateral mass fixation technique with polyaxial screw and rod fixation system.

OBJECTIVE Atlantoaxial instability may result from various pathologic conditions and operative treatment may be required to correct the deformity, provide stability and prevent neurological deficits. We presented our clinic's experience using C1-C2 fusion with polyaxial screw and rod fixation for C1 and C2 instability for various reasons. METHODS AND MATERIAL Four patients with atlantoaxial i...

متن کامل

A novel method of C1–C2 transarticular screw insertion for symptomatic atlantoaxial instability using a customized guiding block

Atlantoaxial instability treated with the C1-2 transarticular screw fixation is biomechanically more stable; however, the technique demanding and the potential risk of neurovascular injury create difficulties for clinical usage, and there is still lack of clinical experience till now.We reported an adult female patient with symptomatic atlantoaxial instability due to rheumatoid arthritis that w...

متن کامل

Posterior Atalntoaxial Fusion with C1 Lateral Mass Screw and C2 Pedicle Screw Supplemented with Miniplate Fixation for Interlaminar Fusion : A Preliminary Report

OBJECTIVE To investigate the feasibility of C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion to treat various atlantoaxial instabilities. METHODS After posterior atlantoaxial fixation with lateral mass screw in the atlas and pedicle screw in the axis, we used 2 miniplates to fixate interlaminar iliac bone graft ...

متن کامل

C2–3 Fusion, C3–4 Cord Compression and C1–2 Posterior Facetal Instability: An Evaluation of Treatment Strategy Based on Four Surgically Treated Cases

STUDY DESIGN Four patients had C2-3 vertebral fusion and radiologically demonstrated cord compression at C3-4 level related to disc bulge with or without association of osteophytes and C1-2 posterior facetal dislocation. The outcome of treatment by atlantoaxial and subaxial facetal fixation is discussed. PURPOSE The article evaluates the significance of atlantoaxial facetal instability in cas...

متن کامل

Atlantoaxial fixation: overview of all techniques.

Over the past century, steady advances have been made in fixating an unstable atlantoaxial complex. Current options for fixation of the atlantoaxial complex include posterior clamps, posterior wiring techniques, C1-C2 transarticular screw fixation, posterior C1 lateral mass screw with C2 pars or pedicle screw fixation, and anterior transoral C1 lateral mass to C2 vertebral body fixation.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Turkish neurosurgery

دوره   شماره 

صفحات  -

تاریخ انتشار 2017