Mirror-orientation noise in a Fabry-Perot interferometer gravitational wave detector.
نویسندگان
چکیده
The influence of angular mirror-orientation errors on the length of a Fabry-Perot resonator is analyzed geometrically. Under conditions in which dominant errors are static or vary slowly over time, the analysis permits a simple prediction of the spectrum of short-term cavity length fluctuations resulting from mirror-orientation noise. The resulting model is applicable to the design of mirror control systems for the Laser Interferometer Gravitational-Wave Observatory, which will monitor separations between mirrored surfaces of suspended inertial test bodies as a way to measure astrophysical gravitational radiation. The analysis is verified by measuring the response of the Laser Interferometer Gravitational- Wave Observatory's 40-m interferometer test-bed to the rotation of its mirrors.
منابع مشابه
Shot noise in gravitational-wave detectors with Fabry-Perot arms.
Shot-noise-limited sensitivity is calculated for gravitational-wave interferometers with Fabry-Perot arms, similar to those being installed at the Laser Interferometer Gravitational-Wave Observatory (LIGO) and the Italian-French Laser Interferometer Collaboration (VIRGO) facility. This calculation includes the effect of nonstationary shot noise that is due to phase modulation of the light. The ...
متن کاملStabilization of a Fabry-Perot interferometer using a suspension-point interferometer
A suspension-point interferometer (SPI) is an auxiliary interferometer for active vibration isolation, implemented at the suspension points of the mirrors of an interferometric gravitational wave detector. We constructed a prototype Fabry-Perot interferometer equipped with an SPI and observed vibration isolation in both the spectrum and transfer function. The noise spectrum of the main interfer...
متن کاملAnalysis of light noise sources in a recycled Michelson interferometer with Fabry-Perot arms.
We present a method by which the effect of laser field variations on the signal output of an interferometric gravitational wave detector is rigorously determined. Using the Laser Interferometer Gravitational Wave Observatory (LIGO) optical configuration of a power recycled Michelson interferometer with Fabry-Perot arm cavities as an example, we calculate the excess noise after the input filter ...
متن کاملA study for reduction of radiation pressure noise in gravitational wave detectors
We describe an experimental conceptual design for observation and reduction of radiation pressure noise. The radiation pressure noise is increased in a high finesse cavity with a small mass mirror. In our experiment a Fabry-Perot Michelson interferometer with a homodyne detection scheme will be built with Fabry-Perot cavities of finesse of 10000 containing suspended mirrors of 23mg. To observe ...
متن کاملHigh-gain power recycling of a Fabry-Perot Michelson interferometer for a gravitational-wave antenna.
Power recycling was implemented on a fully suspended prototype interferometer with arm lengths of 20 m. A wave-front-sensing technique for alignment control of the suspended mirrors was also implemented, which allowed for several hours of stable operation. A power-recycling gain of greater than 12 was achieved, a significant increase over the highest gain in a suspended mirror Fabry-Perot Miche...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 33 18 شماره
صفحات -
تاریخ انتشار 1994