Reservoir Condition Pore-scale Imaging of Multiple Fluid Phases Using X-ray Microtomography
نویسندگان
چکیده
X-ray microtomography was used to image, at a resolution of 6.6 µm, the pore-scale arrangement of residual carbon dioxide ganglia in the pore-space of a carbonate rock at pressures and temperatures representative of typical formations used for CO2 storage. Chemical equilibrium between the CO2, brine and rock phases was maintained using a high pressure high temperature reactor, replicating conditions far away from the injection site. Fluid flow was controlled using high pressure high temperature syringe pumps. To maintain representative in-situ conditions within the micro-CT scanner a carbon fiber high pressure micro-CT coreholder was used. Diffusive CO2 exchange across the confining sleeve from the pore-space of the rock to the confining fluid was prevented by surrounding the core with a triple wrap of aluminum foil. Reconstructed brine contrast was modeled using a polychromatic x-ray source, and brine composition was chosen to maximize the three phase contrast between the two fluids and the rock. Flexible flow lines were used to reduce forces on the sample during image acquisition, potentially causing unwanted sample motion, a major shortcoming in previous techniques. An internal thermocouple, placed directly adjacent to the rock core, coupled with an external flexible heating wrap and a PID controller was used to maintain a constant temperature within the flow cell. Substantial amounts of CO2 were trapped, with a residual saturation of 0.203±0.013, and the sizes of larger volume ganglia obey power law distributions, consistent with percolation theory.
منابع مشابه
Pore-scale contact angle measurements at reservoir conditions using X-ray microtomography
Contact angle is a principal control of the flow of multiple fluid phases through porous media; however its measurement on other than flat surfaces remains a challenge. A new method is presented for the measurement of the contact angle between immiscible fluids at the pore scale at reservoir conditions (10 MPa and 50 C) inside a quarry limestone through the use of X-ray microtomography. It is a...
متن کاملPore-scale Heterogeneity Assessed by the Lattice-boltzmann Method
A digital imaging technique is used to characterize pore-scale structures and to predict fluid flow at the scale. Heterogeneity at the pore-scale can be assessed by the micro-Computed Tomography (micro-CT), which provides complicated boundary conditions of porous media, and it can also be identified by the numerical flow simulation using the lattice-Boltzmann method (LBM) on the digital image. ...
متن کاملMicrotomography and Pore-Scale Modeling of Two-Phase Fluid Distribution
Synchrotron-based X-ray microtomography (micro CT) at the Advanced Light Source (ALS) line 8.3.2 at the Lawrence Berkeley National Laboratory produces threedimensional micron-scale-resolution digital images of the pore space of the reservoir rock along with the spacial distribution of the fluids. Pore-scale visualization of carbon dioxide flooding experiments performed at a reservoir pressure d...
متن کاملPore-by-pore capillary pressure measurements using X-ray microtomography at reservoir conditions: Curvature, snap-off, and remobilization of residual CO2
X-ray microtomography was used to image the shape and size of residual ganglia of supercritical CO2 at resolutions of 3.5 and 2 lm and at representative subsurface conditions of temperature and pressure. The capillary pressure for each ganglion was found by measuring the curvature of the CO2-brine interface, while the pore structure was parameterized using distance maps of the pore space. The f...
متن کاملThe Imaging of Dynamic Multiphase Fluid Flow Using Synchrotron-Based X-ray Microtomography at Reservoir Conditions
Fast synchrotron-basedX-raymicrotomographywas used to image the injection of super-critical CO2 under subsurface conditions into a brine-saturated carbonate sample at the pore-scale with a voxel size of 3.64μm and a temporal resolution of 45s. Capillary pressure wasmeasured from the images by finding the curvature of terminal menisci of both connected and disconnected CO2 clusters. We provide a...
متن کامل