A new shielding calculation method for X-ray computed tomography regarding scattered radiation

نویسندگان

  • Hiroshi Watanabe
  • Kimiya Noto
  • Tomokazu Shohji
  • Yasuyoshi Ogawa
  • Toshioh Fujibuchi
  • Ichiro Yamaguchi
  • Hitoshi Hiraki
  • Tetsuo Kida
  • Kazutoshi Sasanuma
  • Yasushi Katsunuma
  • Takurou Nakano
  • Genki Horitsugi
  • Makoto Hosono
چکیده

The goal of this study is to develop a more appropriate shielding calculation method for computed tomography (CT) in comparison with the Japanese conventional (JC) method and the National Council on Radiation Protection and Measurements (NCRP)-dose length product (DLP) method. Scattered dose distributions were measured in a CT room with 18 scanners (16 scanners in the case of the JC method) for one week during routine clinical use. The radiation doses were calculated for the same period using the JC and NCRP-DLP methods. The mean (NCRP-DLP-calculated dose)/(measured dose) ratios in each direction ranged from 1.7 ± 0.6 to 55 ± 24 (mean ± standard deviation). The NCRP-DLP method underestimated the dose at 3.4% in fewer shielding directions without the gantry and a subject, and the minimum (NCRP-DLP-calculated dose)/(measured dose) ratio was 0.6. The reduction factors were 0.036 ± 0.014 and 0.24 ± 0.061 for the gantry and couch directions, respectively. The (JC-calculated dose)/(measured dose) ratios ranged from 11 ± 8.7 to 404 ± 340. The air kerma scatter factor κ is expected to be twice as high as that calculated with the NCRP-DLP method and the reduction factors are expected to be 0.1 and 0.4 for the gantry and couch directions, respectively. We, therefore, propose a more appropriate method, the Japanese-DLP method, which resolves the issues of possible underestimation of the scattered radiation and overestimation of the reduction factors in the gantry and couch directions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of shielding calculation methods for multi-slice computed tomography (CT) systems.

Currently in the UK, shielding calculations for computed tomography (CT) systems are based on the BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) working group publication from 2000. Concerns have been raised internationally regarding the accuracy of the dose plots on which this method depends and the effect that new scanner technologies may have. A...

متن کامل

Comparison of different methods for shielding design in computed tomography.

The purpose of this work is to compare different methods for shielding calculation in computed tomography (CT). The BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) and NCRP (National Council on Radiation Protection) method were used for shielding thickness calculation. Scattered dose levels and calculated barrier thickness were also compared with th...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

بررسی وضعیت حفاظت در برابر پرتوهای یونیزان در مراکز پرتو تشخیصی ایران: مرور سیستماتیک مقالات منتشر شده

Background and purpose: Increasing number of patients undergoing x-ray examinations has created a global concern due to the deleterious biological effects associated with x-ray exposure. Adherence to ionizing radiation protection principles could be of great benefit in decreasing these effects. Accordingly, the aim of this study was to survey radiation protection in diagnostic x-ray imaging in ...

متن کامل

Monte Carlo simulations of a high-resolution X-ray CT system for industrial applications

An X-ray computed tomography (CT) model based on the GEANT4 Monte Carlo code was developed for simulation of a cone-beam CT system for industrial applications. The full simulation of the X-ray tube, object, and area detector was considered. The model was validated through comparison with experimental measurements of different test objects. There is good agreement between the simulated and measu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2017