Comparison of the biometric measurements calculated with Zeiss IOL-Master and WaveLight OB-820
نویسندگان
چکیده
BACKGROUND The primary objective of this study was to investigate the level of agreement between IOL-Master and OB-820 ocular biometers. MATERIALS AND METHODS In this prospective randomized case series, we measured the anterior chamber depth (ACD), the axial length (AL), the corneal radii (R1, R2), the ratio of mean corneal radius and spherical equivalent and the corneal astigmatism (cylinder [Cyl]) before and after cataract extraction surgery. RESULTS Significant differences between pre- and postoperative data were observed for ACD for both biometric devices (P<0.01) and Cyl parameter in IOL-Master. Range and 95% limits of agreement (LoA) were clinically significantly different for AL parameter pre- and postoperatively and for R2 and radius and spherical equivalent postoperatively (P<0.001). The rest of the parameters presented sufficient 95% LoA, which imply good agreement. CONCLUSION In clinical practice, the IOL-master and OB-820 should not be used interchangeably due to discrepancy in the important AL parameter. Both biometers may provide consistent results regarding Cyl, ACD and R1.
منابع مشابه
مقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملThe efficiency of aspheric intraocular lens according to biometric measurements
PURPOSE To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. METHODS This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm...
متن کامل[Contact lenses and intraocular lens power calculation: refractive surprise using the IOLMaster non-contact biometric method].
Dear Sir, This letter is to alert about the danger of carrying out biometric calculations for the intraocular lens without being aware that the patient may be using a contact lens. This warning is valid even when the highest precision research technology is being utilised. At present, errors in the calculation of the intraocular lens (IOL) are the most frequent cause of lens exchanges as well a...
متن کاملClinical Efficacy and Complications of Intraocular Lens Exchange for Opacified Intraocular Lenses
PURPOSE To evaluate the clinical efficacy and complications of intraocular lens (IOL) exchange. METHODS A review of medical records was performed for 52 eyes that had undergone an IOL exchange due to IOL opacification. Surgical complications and their incidences were analyzed. The mean best corrected visual acuity (BCVA) after the IOL exchange was compared with the mean pre-exchange BCVA and ...
متن کاملAccuracy of intraocular lens power calculations using the Zeiss IOL master. A prospective study.
PURPOSE Partial Coherence Interferometry (PCI) is a fast, noncontact method to calculate lens implant power for cataract surgery. It has been reported as a potentially more accurate method than ultrasound biometry. Prospective study of the refractive outcomes of a consecutive series of patients undergoing phacoemulsification surgery with preoperative biometry by both ultrasound A-scan and PCI. ...