IGRT versus non-IGRT for postoperative head-and-neck IMRT patients: dosimetric consequences arising from a PTV margin reduction
نویسندگان
چکیده
BACKGROUND To evaluate the impact of image-guided radiation therapy (IGRT) versus non-image-guided radiation therapy (non-IGRT) on the dose to the clinical target volume (CTV) and the cervical spinal cord during fractionated intensity-modulated radiation therapy (IMRT) for head-and-neck cancer (HNC) patients. MATERIAL AND METHODS For detailed investigation, 4 exemplary patients with daily control-CT scans (total 118 CT scans) were analyzed. For the IGRT approach a target point correction (TPC) derived from a rigid registration focused to the high-dose region was used. In the non-IGRT setting, instead of a TPC, an additional cohort-based safety margin was applied. The dose distributions of the CTV and spinal cord were calculated on each control-CT and the resulting dose volume histograms (DVHs) were compared with the planned ones fraction by fraction. The D50 and D98 values for the CTV and the D5 values of the spinal cord were additionally reported. RESULTS In general, the D50 and D98 histograms show no remarkable difference between both strategies. Yet, our detailed analysis also reveals differences in individual dose coverage worth inspection. Using IGRT, the D5 histograms show that the spinal cord less frequently receives a higher dose than planned compared to the non-IGRT setting. This effect is even more pronounced when looking at the curve progressions of the respective DVHs. CONCLUSIONS Both approaches are equally effective in maintaining CTV coverage. However, IGRT is beneficial in spinal cord sparing. The use of an additional margin in the non-IGRT approach frequently results in a higher dose to the spinal cord than originally planned. This implies that a margin reduction combined with an IGRT correction helps to maintain spinal cord dose sparing best as possible. Yet, a detailed analysis of the dosimetric consequences dependent on the used strategy is required, to detect single fractions with unacceptable dosimetric deviations.
منابع مشابه
Single Institution’s Dosimetry and IGRT Analysis of Prostate SBRT
BACKGROUND AND PURPOSE To report single institution's IGRT and dosimetry analysis on the 37 Gy/5 fraction prostate SBRT clinical trial. MATERIALS/METHODS The IRB (Duke University Medical Center) approved clinical trial has treated 28 patients with stage T1-T2c prostate cancer with a regimen of 37 Gy in 5 fractions using IMRT and IGRT protocols since 2009. The clinical trial protocol requires ...
متن کاملEffectiveness of image-guided radiotherapy for laryngeal sparing in head and neck cancer.
We would like to compare the effectiveness of image-guided (IGRT) and intensity-modulated (IMRT) radiotherapy to spare the larynx in head and neck cancer patients. A retrospective review of 48 patients undergoing radiation for non-laryngeal and non-hypopharyngeal head and neck cancers. Mean laryngeal and hypopharyngeal dose was compared between 11 patients treated with IMRT and 37 patients trea...
متن کاملImage Guided Radiation Therapy (IGRT) Practice Patterns and IGRT's Impact on Workflow and Treatment Planning: Results From a National Survey of American Society for Radiation Oncology Members.
PURPOSE To survey image guided radiation therapy (IGRT) practice patterns, as well as IGRT's impact on clinical workflow and planning treatment volumes (PTVs). METHODS AND MATERIALS A sample of 5979 treatment site-specific surveys was e-mailed to the membership of the American Society for Radiation Oncology (ASTRO), with questions pertaining to IGRT modality/frequency, PTV expansions, method ...
متن کاملThe frequency of re-planning and its variability dependent on the modification of the re-planning criteria and IGRT correction strategy in head and neck IMRT
BACKGROUND To analyse the frequency of re-planning and its variability dependent on the IGRT correction strategy and on the modification of the dosimetric criteria for re-planning for the spinal cord in head and neck IG-IMRT. METHODS Daily kV-control-CTs of six head and neck patients (=175 CTs) were analysed. All volumes of interest were re-contoured using deformable image registration. Three...
متن کاملReduced volume SIB-IMRT/IGRT to head and neck cancer in elderly and frail patients: outcome and toxicity
BACKGROUND Especially elderly and frail patients have a limited ability to compensate for side effects of a radical treatment of head and neck malignancies. Limiting the target volume to the macroscopic disease, without prophylactic nodal irradiation, might present a feasible approach for these patients. The present work therefore aims evaluating an IMRT/IGRT -SIB concept for safety and efficac...
متن کامل