Dynamic force measurements of avidin-biotin and streptavdin-biotin interactions using AFM.

نویسندگان

  • Marzena de Odrowaz Piramowicz
  • Paweł Czuba
  • Marta Targosz
  • Kvetoslava Burda
  • Marek Szymoński
چکیده

Using atomic force microscopy (AFM) we performed dynamic force measurements of the adhesive forces in two model systems: avidin-biotin and streptavidin-biotin. In our experiments we used glutaraldehyde for immobilization of (strept)avidin on the tip and biotin on the sample surface. Such interface layers are more rigid than those usually reported in the literature for AFM studies, when (strept)avidin is coupled with biotinylated bovine albumin and biotin with agarose polymers. We determined the dependence of the rupture forces of avidin-biotin and streptavidin-biotin bonds in the range 300-9600 pN/s. The slope of a semilogarithmic plot of this relation changes at about 1700 pN/s. The existence of two different regimes indicates the presence of two activation barriers of these complexes during the dissociation process. The dissociation rates and activation energy barriers, calculated from the Bell model, for the avidin-biotin and streptavidin-biotin interactions are similar to each other for loading rates > 1700 pN/s but they are different from each other for loading rates < 1700 pN/s. In the latter case, the dissociation rates show a higher stability of the avidin-biotin complex than the streptavidin-biotin complex due to a larger outer activation barrier of 0.8 k(B)T. The bond-rupture force is about 20 pN higher for the avidin-biotin pair than for the streptavidin-biotin pair for loading rates < 1700 pN/s. These two experimental observations are in agreement with the known structural differences between the biotin binding pocket of avidin and of streptavidin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Force Spectroscopy of Single Molecule

The direct measurement of forces between individual receptor-ligand complexes is an emerging new field. With the atomic force microscope (AFM) it has been possible to probe the forces between a range of biological molecules, including complementary oligo-nucleotides, proteins and carbohydrate interactions. To date, the force required to rupture these single ligandreceptor interactions is common...

متن کامل

A molecular delivery system by using AFM and nanoneedle.

We developed a new low invasive cell manipulation and gene or molecule transfer system in a single living cell by using an atomic force microscope (AFM) and ultra thin needle, a nanoneedle. DNA was immobilized on the surface of the nanoneedle by covalent bonding and avidin-biotin affinity binding. Immobilization of DNA on the nanoneedle was confirmed by measuring the unbinding force between avi...

متن کامل

Direct force measurements of the streptavidin-biotin interaction.

The interaction between streptavidin and its ligand, biotin, were studied by direct force measurements. The complimentary approaches of surface force apparatus (SFA) and atomic force microscopy (AFM) were used to elucidate both long-range and short-range adhesive interactions of the streptavidin biotin interaction. The high spatial resolution of the SFA provided a detailed profile of the inters...

متن کامل

pH-dependent deformations of the energy landscape of avidin-like proteins investigated by single molecule force spectroscopy.

Avidin and avidin-like proteins are widely used in numerous techniques since the avidin-biotin interaction is known to be very robust and reliable. Within this study, we investigated this bond at the molecular level under harsh conditions ranging from very low to very high pH values. We compared avidin with streptavidin and a recently developed avidin-based mutant, chimeric avidin. To gain insi...

متن کامل

Molecular dynamics study of unbinding of the avidin-biotin complex.

We report molecular dynamics simulations that induce, over periods of 40-500 ps, the unbinding of biotin from avidin by means of external harmonic forces with force constants close to those of AFM cantilevers. The applied forces are sufficiently large to reduce the overall binding energy enough to yield unbinding within the measurement time. Our study complements earlier work on biotin-streptav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta biochimica Polonica

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2006