Sampling systems for visual field assessment and computerised perimetry.
نویسندگان
چکیده
Three successive stages in the representations of the visual image are studied by computations from the best available data. The results are embodied in projections, drawn automatically. These projections are related to the assessment of visual disability and the dimensions of lesions in the retina and visual pathway. Fields can be assessed visually with the aid of graticules or directly during computerised perimetry.
منابع مشابه
Oculokinetic perimetry for the assessment of visual fields.
The visual fields of 13 children aged 7 to 16 (mean 10.7 years) were assessed by oculokinetic perimetry (OKP), a technique where the field of vision is tested at reading distance using a simple chart, and the results compared with conventional Goldmann perimetry. Cooperation with testing was greater for OKP than Goldmann perimetry and in some cases OKP was better correlated with clinical findin...
متن کاملComparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields
PURPOSE To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. METHODS Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of ...
متن کاملCentral visual field sensitivity data from microperimetry with spatially dense sampling
Microperimetry, also referred to as fundus perimetry or fundus-driven perimetry, enables simultaneous acquisition of visual sensitivity and eye movement data. We present sensitivity data collected from 60 participants with normal vision using gaze-contingent perimetry. A custom designed spatially dense test grid was used to collect data across the visual field within 13° of fixation. These data...
متن کاملComparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases
Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...
متن کاملOculokinetic perimetry: a simple visual field test for use in the community.
A method of visual field examination is described which enables an unsupervised person to carry out self-assessment using only a paper test chart, a record sheet, and a pencil. It is entitled 'oculokinetic perimetry' because it is the subject's eye that moves and not the test target. By providing non-ophthalmic health care workers with a simple means of performing perimetry in the community, an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 64 9 شماره
صفحات -
تاریخ انتشار 1980