Performance of a Small Portal Using Integrated Germanium Detector Modules

نویسندگان

  • Ronald M. Keyser
  • Timothy R. Twomey
چکیده

Portal monitors and mobile search systems are most effective in positive identification when constructed with high resolution detectors. To satisfy the need for this type of detector, an integrated gamma ray spectrometer, incorporating a germanium detector with integral mechanical cooling, digital signal processing electronics, MCA, and communications has been developed. This modular subsystem has been used in a several different applications, including use in stationary and mobile systems for the detection and identification of radioactive materials. To have the sensitivity needed for these applications the detectors must have good low and medium energy detection efficiency coupled with excellent spectral peak resolution. The high resolution is needed to remove peak overlaps and overcome the problems of masking of SNM with common nuclides. In either situation where the spectrometer and the source are moving relative to one another, the Field of View (FOV) determines the time the radioactive material contributes to the data in the spectrum. The absolute efficiency and background (i.e., signal-to-noise ratio) determine the minimum detectable or identifiable quantity for the material in the FOV. The uniformity of the performance of several units over the energy range of 80 keV to 1.8 MeV was previously reported. A portal monitor was constructed with 8 detectors and the performance measured for several common test nuclides. The total height of the detection zone is 2 meters with 4 detectors uniformly spaced on each side. In this portal, the horizontal FOV is limited by steel collimators. The vertical FOV was not collimated. The background was measured in low background and elevated (NORM) background situations. The measurements presented show this unit can be applied to a wide variety of monitoring situations for the detection of illicit material.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of a Radiation Portal Freight Monitor based on Integrated Germanium Detector Modules

Portal monitors, container scanners, and mobile search systems, constructed with high resolution germanium (HPGe) detectors, are currently being installed at locations world-wide. This reflects a general desire for improved performance and a reduction in the time to make a good decision in interdiction cases. An integrated gamma-ray spectrometer, incorporating a mechanically-cooled HPGe detecto...

متن کامل

Performance Characteristics of a Third-generation Spectroscopic Vehicle Portal Monitor based on High Purity Germanium Detectors

The general need for improved detection performance and reduced decision time for portal monitors, freight container scanners, and mobile search systems is being achieved with systems utilizing High-Purity Germanium (HPGe) detectors. Highly specialized software analyzes the spectroscopic data to produce accurate results in live time. To meet the need, a new generation monitor has been developed...

متن کامل

Characteristics of an Integrated Germanium Detector Based

An integrated gamma ray spectrometer, incorporating a germanium detector with integral mechanical cooling, digital signal processing electronics, MCA, and communications has been developed. It is intended as a modular subsystem for wide application, including use in stationary or mobile systems for the detection of radioactive materials. The requirements for this application are good low and me...

متن کامل

Characteristics of an Integrated Gamma-Ray Spectrometer Using Germanium Detectors in Fixed and Mobile Measurement Systems

To address the need for high resolution detection systems to be used in portal monitors and mobile search systems, an integrated gamma ray spectrometer, incorporating a germanium detector with integral mechanical cooling, digital signal processing electronics, MCA, and communications has been developed. This modular subsystem can be used in a wide variety of applications, including use in stati...

متن کامل

Evaluation of the Portal Imaging System Performance for an Elekta Precise Linac in Radiotherapy

Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008