Can transcranial Doppler discriminate between solid and gaseous microemboli? Assessment of a dual-frequency transducer system.

نویسندگان

  • Hugh S Markus
  • Martin Punter
چکیده

BACKGROUND AND PURPOSE Transcranial Doppler ultrasound can reliably detect both gaseous and solid cerebral emboli. However, conventional equipment is unable to discriminate between gaseous and solid emboli. This is a major limitation in situations in which the 2 coexist, because they may have very different clinical relevance. Recently, a novel Embo-Dop system, using insonation at 2 ultrasound transducer frequencies, has been developed. An initial study with a small sample size suggested it provided excellent discrimination. We performed a validation study in subjects with embolic signals of known nature. METHODS Gaseous embolic signals were obtained in 7 patients with known patient foramen ovale by intravenous injection of agitated saline injections. Solid embolic signals were obtained in patients with symptomatic carotid stenosis (N=23). Discrimination of the 2 using the Embo-Dop system dual-frequency system was assessed. It was compared with discrimination using embolic signal maximum intensity with an intensity threshold. RESULTS One hundred forty-five solid embolic signals were recorded from carotid stenosis patients. Seventy-three were classified as solid and 72 as gaseous by the Embo-Dop system. Six hundred forty-eight gaseous embolic signals were recorded from 7 patients with patent foramen ovale. Six hundred twenty-five were classified as gaseous and 23 as solid. This gave a sensitivity of 50.3% and specificity of 96.5% for detecting solid embolic signals. Discrimination was better than using a simple intensity threshold. CONCLUSIONS The Embo-Dop dual-frequency system allows better discrimination than a simple intensity threshold but it is not accurate enough for use in clinical or research studies. Further work is needed to develop reliable clinical systems for discrimination of emboli.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler.

BACKGROUND AND PURPOSE The aim of this study was to assess the first multifrequency transcranial Doppler system that was specially developed to automatically detect and discriminate between solid and gaseous cerebral microemboli. METHODS The multifrequency transcranial Doppler instrumentation insonates simultaneously with 2.5 and 2.0 MHz. Differentiation between solid and gaseous microemboli ...

متن کامل

Solid cerebral microemboli and cerebrovascular symptoms in patients with prosthetic heart valves.

BACKGROUND AND PURPOSE Although cerebral microemboli are often detected by transcranial Doppler ultrasonography in mechanical heart valve patients, the clinical significance of such microemboli is unclear. The aim of this study was to determine the frequency and composition of cerebral microemboli in a prosthetic heart valve population and to correlate these findings to cerebrovascular symptoms...

متن کامل

Cerebral microemboli and brain injury during carotid artery endarterectomy and stenting.

BACKGROUND AND PURPOSE Cerebral microembolic signals detected by transcranial Doppler are frequent during carotid angioplasty with stenting and carotid endarterectomy (CEA). Their potential harmful effects on the brain are, however, unclear. The aim of this study was to relate the frequency and type of per-procedural microembolic signals to procedure-related ipsilateral ischemic strokes and new...

متن کامل

Automatic classification of HITS into artifacts or solid or gaseous emboli by a wavelet representation combined with dual-gate TCD.

BACKGROUND AND PURPOSE Transcranial Doppler (TCD) can detect high-intensity transient signals (HITS) in the cerebral circulation. HITS may correspond to artifacts or solid or gaseous emboli. The aim of this study was to develop an offline automated Doppler system allowing the classification of HITS. METHODS We studied 600 HITS in vivo, including 200 artifacts from normal subjects, 200 solid e...

متن کامل

Embolus differentiation using multifrequency transcranial Doppler.

Embolus Differentiation Using Multifrequency Transcranial Doppler To the Editor: Markus and Punter report disappointing results for differentiation between solid and gaseous emboli using both the default settings of the Embo-Dop multifrequency transcranial Doppler system,1 and the modified criteria recommended by Russell and Brucher.2,3 One reason for this poor performance is a fundamental limi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 36 8  شماره 

صفحات  -

تاریخ انتشار 2005