Comparison of urine dipsticks with quantitative methods for microalbuminuria.

نویسندگان

  • M J Pugia
  • J A Lott
  • L W Clark
  • D R Parker
  • J F Wallace
  • T W Willis
چکیده

We describe a new dip- and read dipstick that detects urine albumin at concentrations of 10 mg/l and above and urine creatinine at concentrations of 300 mg/l and above. The albumin assay is based on a high-affinity, dye-binding technique while the creatinine assay is based on the peroxidase-like activity of copper creatinine complexes. With these two-test dipsticks, urines from normal adults supplemented with albumin and creatinine were correctly identified to within +/- 15% of the expected value for both analytes; the between-day coefficients of variation ranged from 7.1% to 16.1%. We tested 275 patients' unmodified urines by the Bayer and Boehringer Mannheim Micral-Test albumin dipsticks and for albumin with the Beckman Array on the same specimens. We also analyzed 42 selected urines from the group of 275 for albumin by another quantitative immunochemical method and by electrophoresis plus a total protein method to estimate the albumin concentration. The quantitative immunochemical methods appear to underestimate the urine albumin concentrations; in these 42 urines measured as negative, i.e., < ca. 16-20 mg/l, by one of the quantitative method but positive by the Bayer dipstick, 33 of these were positive by the electrophoresis/total protein assay combination. The Bayer albumin dipstick correctly identified urines as having < 16 mg/l or > or = 16 mg/l at an 80% rate. At a cutoff of 20 mg/l, the rate increased to 87%. We also determined the urinary albumin/creatinine ratios on the 275 patients using the Bayer two-pad dipstick and found agreement 84% of the time with the same ratio obtained from a quantitative immunochemical method for albumin and a rate-Jaffe method for creatinine; an albumin/creatinine ratio (mg/g) of 30 was used as the discrimination point. Albumin stability studies performed on the Beckman Array patients with six fresh urines showed small but consistent decreases at -20 degrees C but not at 4 degrees C after one month of storage. The albumin in contrived urines, as estimated by electrophoreses/total protein and by the dipsticks did not change at these storage conditions. Boric acid at 1 g/l as a urine preservative had no effect on the measurement of albumin by any of the methods described here nor of the assay of creatinine. Other urinary proteins present at abnormal excretion rates did not interfere with the Bayer albumin dipstick. Abnormal concentrations of bilirubin, citrate, creatine, ascorbic acid, albumin, hemoglobin and myoglobin in urine did not interfere with the creatinine dipstick measurements. The first four of the above did not affect the Bayer dipstick results for albumin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی روش‌های الکتروایمونواسی و 100Clinitek- برای تشخیص میکروآلبومینوری

Evaluation of Electroimmunoassay and Clinitek-100 for Detection of Microalbuminuria B.A. Jalali Khanabadi PhD , H. Mozaffari Khosravi PhD Received: 12/10/05 Sent for Revision: 04/03/06 Received Revised Manuscript: 20/01/07 Accepted: 25/01/07 Background and Objective: Detection of microalbuminuria is an important laboratory test for evaluation of diabetic complications. A reliable me...

متن کامل

Original Research: Evaluation of point-of-care tests for detecting microalbuminuria in diabetic patients

The prevention of chronic disorders is one of the most important cornerstones of primary health care. Screening for microalbuminuria is valuable in primary health care, as microalbuminuria is the earliest manifestation of nephropathy, and an independent marker of increased cardiovascular morbidity and mortality in diabetic,1 as well as non-diabetic, patients.2 The presence of microalbuminuria s...

متن کامل

Comparison of several methods for semiquantitative determination of urinary protein.

Two types of urine protein dipsticks and the sulfosalicylic acid method were compared for their accuracy and specificity, with use of urine samples supplemented with various proteins. Dipsticks yield accurate results when the protein under consideration is restricted to albumin; the sulfosalicylic acid method accurately determines many kinds of proteins in addition to albumin. Detergents affect...

متن کامل

The primary care perspective on routine urine dipstick screening to identify patients with albuminuria.

Proponents of routine urine dipstick screening to identify patients at risk for ESRD in the primary care setting have argued that urine dipsticks are inexpensive, low risk, acceptable to patients, and now, more accurate. Proponents believe that urine dipstick screening has the potential to improve outcomes for people with early disease and increase awareness of CKD. Most primary care physicians...

متن کامل

Comparison of the Efficacy of Serum Creatinine and Microalbuminuria in Early Diagnosis of Renal Injury in Asphyxiated Infants in Calabar, Southern Nigeria

Background: Microalbuminuria and serum creatinine are the specific markers of acute renal injury. Perinatal asphyxia is responsible for 50% of all neonatal deaths and nonoliguric acute renal injuryis one of its complications. This study was undertaken to determine the efficacy of serum creatinine and microalbuminuria for early diagnosis of renal injury in severely asphyxiated neonates in Calaba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies

دوره 35 9  شماره 

صفحات  -

تاریخ انتشار 1997