Ability to achieve gain/frequency response and SSPL-90 under three prescription formulas with in-the-ear hearing aids.

نویسندگان

  • C A Sammeth
  • B F Peek
  • G W Bratt
  • F H Bess
  • S M Amberg
چکیده

Custom in-the-ear (ITE) hearing aids (standard linear amplifiers with single-pole-filter low-frequency tone control and a class A amplifier output stage) were fit to 90 ears using the revised National Acoustics Laboratories' formula (NAL-R), and to 20 ears each using Prescription of Gain/Output II (POGO II) and Memphis State University (MSU) formulas. Both real-ear insertion gain and 2-cc coupler gain were evaluated. Examination of differences between prescribed gain and that actually achieved in the fittings revealed that too much gain was often given in the low- and mid-frequency range and insufficient gain in the high frequencies. There was little difference among the formulas in the degree of deviation from target. For some fittings, the deviation resulted in poorer predicted speech recognition scores (modified Speech Transmission Index). For the POGO II and MSU methods, underfitting of prescribed SSPL-90 values was far more common than overfitting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of in-the-ear and over-the-ear hearing aid fittings.

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE...

متن کامل

The value of routine real ear measurement of the gain of digital hearing aids.

The main aims of this study were: (1) to determine whether routine real ear insertion gain (REIG) measurement is necessary in fitting digital hearing aids; and (2) to assess the extent to which modifying the frequency-gain response of an aid can lead to better matches to the target in cases where the target gain was not initially achieved. The target formula was selected as NAL-NL1 in the progr...

متن کامل

Evaluation of an in-situ output probe-microphone method for hearing aid fitting verification.

Several hearing aid prescription procedures specify frequency gain functions in terms of the desired levels of amplified speech. The most direct method for verifying hearing aid fittings based on these procedures requires a measurement of amplified speech in the ear canal. This paper describes the evaluation of a probe microphone measurement procedure designed to measure amplified speech to ver...

متن کامل

Achieving prescribed gain/frequency responses with advances in hearing aid technology.

Technological limitations have restricted the capability of older generation in-the-ear (ITE) hearing aids to closely match prescribed real ear gain/frequency responses. Newer technology, widely available in currently marketed ITE hearing aids, has considerably improved this capability. Data for 60 ears are presented comparing the real ear insertion gain (REIG) actually achieved to the target R...

متن کامل

Comparison of frequency response and aided speech-recognition performance for hearing aids selected by three different prescriptive methods.

The gain and the speech-recognition performance obtained for behind-the-ear (BTE) hearing aids selected by different prescriptive methods was compared. The three prescriptive methods examined were the NAL-revised method, the Memphis State or COX method, and the POGO-II procedure. Twelve subjects had hearing aids and earmolds selected to match the prescription made by each method. Once selected,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 4 1  شماره 

صفحات  -

تاریخ انتشار 1993