Performance Evaluation of a miniPET Camera for Brain Scanning
نویسندگان
چکیده
A nuclear miniPET camera was constructed with 2 bucket rings, each having 8 BGO detector modules for brain scanning. After calibration of the camera, an experimental investigation of sensitivity was carried out to evaluate the performance of this PET scanner. The characteristics of NECR were examined for comparisons of count rate considering the statistical noise due to scattered and random events. NECR performance was observed using 10 cm diameter phantom filled with 1 L water and 240 MBq of 18F. All data were acquired in 2D acquisition mode but without septa. Randoms were estimated by introducing delay into the coincidence circuit which was an extra 100 ns time delay. Multiples were recorded simultaneously with the prompt and delayed events. The true plus scattered coincidence events were calculated as the difference between prompt and random plus multiple events. After recording all the data, the noise equivalent count rate (NECR) was calculated and graphically presented. It is observed that NEC value is significantly lower than other similar scanners. Comparing the individual components of the count rate, a much higher randoms rate is observed for the camera because of the absence of any side shielding, so that out of field activity contributes significantly to the randoms rate and hence reduces the NECR value.
منابع مشابه
Applications of Tomographic Imaging in Nuclear Medicine
..................................................................................................................................... 2 Glossary ..................................................................................................................................... 4 List of papers ........................................................................................................
متن کاملEvaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators
Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...
متن کاملMonte Carlo simulations of a small-animal PET scanner
The work here presented analyzes the performances (in terms of scatter fraction, spatial resolution, sensitivity, image quality) obtained from a 10detectors small-animal PET, simulated via Geant4 Application for Emission Tomography (GATE), in comparison with other designs studied in previous works. Particular attention is given to the comparison with the 12-detectors miniPET II, already built a...
متن کاملEvaluation of performance quality of SPECT camera in Shariati Hospital of Tehran University of Medical Sciences [Persian]
In nuclear medicine, there are two methods of imaging, planar and tomography. Single photon emission computerized tomography (SPECT) shows better image details and therefore is influenced more by image parameters such as resolution, uniformity, sensitivity, etc. Manufacturers provide customers with data which are obtained by complicated and sometimes secret methods. Marketing companies te...
متن کاملEvaluation of role of brain SPECT in diagnosis of post stroke dementia [Persian]
Post stroke dementia is one of the most common complications of stroke that is preventable and relatively treatable too. The purpose of the study is comparison between the positive findings in brain CT scan and brain perfusion SPECT. 15 patients who were complicated by dementia after cerebrovascular accident and also 5 patients as a control group enrolled in this study. Brain CT scan and ...
متن کامل