[Evaluation of a method for correcting systematic setup error in external-beam radiation therapy].
نویسندگان
چکیده
BACKGROUND AND PURPOSE We verified the propriety of our systematic error reduction strategy by means of a computer simulation based on our data of position error with a prone fixation device for prostate IMRT. MATERIALS AND METHODS Computer simulations of the off-line correction method for systematic setup errors based on the portal imaging taken on the first several days of the treatment session were performed. Using the computer simulations, an optimal number of portal images were evaluated for the SD value, from 0.5 mm to 1.5 mm at a 0.25 mm interval, and the respective required setup margins were calculated. RESULTS The value of systematic error was reduced as the frequency of data obtained increased. Moreover, the reduction rate was so remarkable that random error was large.
منابع مشابه
A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کاملDosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients
Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...
متن کامل[Evaluation of setup error and adequate setup margins in patients with prostate cancer treated by IMRT and fixed in the prone position using a set of immobilization devices].
PURPOSE Positional reproducibility in patients with prostate cancer fixed in the prone position with a set of immobilization devices for external-beam intensity-modulated radiation therapy (IMRT) was evaluated. In addition, the adequacy of our positional error reduction strategy and current planning target volume (PTV) margins was also evaluated. RESULTS Systematic error was corrected by the ...
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملEvaluation of Accuracy and Quality assurance of external beam therapy with photons
Introduction: Receiving exact dose by the patients is vital in radiotherapy. In radiation therapy, the dosimetry of radiations is too important because of successful radiation inquires for delivering the exact dose to the target volume. This study is to evaluate the tolerances and the accuracy of calculated dose of photon beams in the treatment software system. The TECDOC1583 p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nihon Hoshasen Gijutsu Gakkai zasshi
دوره 64 1 شماره
صفحات -
تاریخ انتشار 2008