Output and aerosol properties of 5 nebulizer/compressor systems with arformoterol inhalation solution.
نویسندگان
چکیده
BACKGROUND Arformoterol, the (R,R) isomer of formoterol, is approved as an inhalation solution for the treatment of bronchoconstriction in patients with chronic obstructive pulmonary disease. Multiple nebulizer systems are commercially available. Different nebulizers can differ significantly in drug output, which may impact drug delivery and clinical efficacy. This study compared the aerosol properties of arformoterol delivered via 5 commonly used nebulizer systems for the home-care market. METHODS The delivered dose of arformoterol inhalation solution (15 microg/2 mL) was collected in a glass Dreschel-type apparatus. The delivered amount in fine-droplet fraction was assessed with an Andersen cascade impactor, and droplet size (average median diameter and average percent<5 microm) was evaluated via laser diffraction. Compressor flow rate measurements were taken after 1 min and 6 min by placing the flow meter in line with each system. RESULTS The Pari LC Plus, Updraft II Opti-Neb, and NebuTech systems delivered similar amounts of the 15-microg nominal dose (from 23% to 25%). The Pari LC Star and Sidestream systems delivered slightly higher doses (31% and 35%, respectively). The nebulizer/compressor systems differed somewhat with respect to droplet size. The NebuTech delivered the lowest fine-droplet fraction (61%) via Andersen cascade impactor, and the smallest percent of droplets<5 microm (40%) via laser diffraction. The Pari LC Star and Sidestream delivered the highest fine-droplet fraction (100% and 93%, respectively), and the greatest percent of droplets<5 microm (84% and 88%). The fine-droplet fractions for the Updraft II Opti-Neb and Pari LC Plus were 93% and 89%, respectively, and the percent of droplets<5 microm was about 67%. Compressor flow rates ranged from 3.2 L/min (Pari LC Plus) to 5.4 L/min (NebuTech). CONCLUSIONS The results of this study demonstrate that the choice of nebulizer/compressor system can influence the aerosol properties of arformoterol inhalation solution and should be considered when prescribing nebulized medications.
منابع مشابه
In vitro delivery of budesonide from 30 jet nebulizer/compressor combinations using infant and child breathing patterns.
BACKGROUND An aerosol of budesonide inhalation suspension is delivered when used with various jet-nebulizer/compressor combinations. The constant introduction of new nebulizer/compressor combinations raises the question of whether the performance of these match the performance of existing devices. The aim of this study was to determine in vitro the inhaled mass and aerosol characteristics of bu...
متن کاملIs the measurement of delivered dose a good performance measure? A characterization of delivered and respirable delivered dose in two brands of jet nebulizer
Background Use of a nebulizer facilitates rapid administration of high doses of drug, which is desirable for patients presenting with acute severe asthma. Breath-enhanced jet nebulizers direct the patient’s air flow through the nebulizer handset during inhalation producing aerosol output with a more favorable respirable profile. SideStream Plus (SS+; Philips Respironics) and Nebutech (NB; Salte...
متن کاملComparison of twenty three nebulizer/compressor combinations for domiciliary use.
We have assessed the physical and dynamic characteristics of 23 home jet nebulizer/compressor combinations currently available in the UK and Europe. The combinations were evaluated in terms of pressure-flow characteristics, aerosol mass distribution, volume output, electrical costs, and sound level. In addition, we determined the effect of nebulizer fill volume on aerosol mass distribution and ...
متن کاملSuitability of caspofungin for aerosol delivery: physicochemical profiling and nebulizer choice.
BACKGROUND Aerosolized antifungal therapy is a promising route of drug delivery for pulmonary aspergillosis due to attainment of high localized concentrations. Caspofungin, a new antifungal agent with proven efficacy against invasive aspergillosis, has ideal potential for aerosolization. STUDY OBJECTIVE To examine in vitro the suitability of caspofungin for aerosol administration by character...
متن کاملDynamics of aerosol size during inhalation: hygroscopic growth of commercial nebulizer formulations.
The size of aerosol particles prior to, and during, inhalation influences the site of deposition within the lung. As such, a detailed understanding of the hygroscopic growth of an aerosol during inhalation is necessary to accurately model the deposited dose. In the first part of this study, it is demonstrated that the aerosol produced by a nebulizer, depending on the airflows rates, may experie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 54 10 شماره
صفحات -
تاریخ انتشار 2009