Morphology of the stromal surface and endothelium using two different microkeratomes.
نویسندگان
چکیده
PURPOSE To compare stromal surface and endothelial morphology after keratectomies and after laser in situ keratomileusis (LASIK), using two different microkeratomes. METHODS Keratectomies (160-microm and 400-microm) were performed on 82 enucleated porcine eyes using the Chiron Automated Corneal Shaper (52 eyes) and the Microtech Turbokeratome (30 eyes). LASIK procedures of -9.00 D, -27.00 D, and -36.00 D were performed with a Schwind excimer laser. The corneas were immediately fixed in glutaraldehyde or stained with alizarin red and trypan. Scanning electron microscopy was then performed. RESULTS All keratectomies performed with the Chiron microkeratome displayed a relatively smooth surface. The quality of the keratectomies with the manually advanced Microtech microkeratome was variable, with a high incidence (4 of 9) of incomplete cuts and irregular surfaces. In the eyes in which the stromal laser ablation was performed, a thin layer of condensed stroma (pseudomembrane formation) was seen. Vital staining did not indicate endothelial damage. CONCLUSIONS The surface morphology was unacceptable for one of the microkeratomes tested. Keratectomies of 160 to 400 microm and LASIK up to -36.00 D did not acutely alter endothelial morphology in porcine eyes.
منابع مشابه
Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis
PURPOSE Femtosecond lasers have become the standard for laser-assisted in situ keratomileusis (LASIK) flap creation, but advanced mechanical microkeratomes are still an alternative, more cost-effective way to create the flap. The SCHWIND Carriazo-Pendular microkeratome is one of the most commonly used microkeratomes. The influence of different cutting parameters (head-advance speeds, cutting he...
متن کاملDip coating of silica layer on melt-spun Finemet ribbons: surface morphology and electrical resistivity changes
In this study, melt-spun Finemet ribbons were coated by a thin layer of SiO2 using dip coating method. Amorphous ribbon prepared by melt spinning method and dip coating were done by using a solution of tetraethylen orthosilicate as a SiO2 precursor, ethanol as solvent and distilled water for hydrolysis. Different thicknesses of SiO2 layer, namely 304, 349, 451, 526 and 970 nm were obtained prop...
متن کاملCut edges and surface characteristics produced by different microkeratomes.
PURPOSE To determine the cutting characteristics of seven different microkeratomes and to compare the cut edges and surface characteristics of the corneas with respect to different keratome parameters, ie, blade oscillation frequencies and keratome speed. METHODS Lamellar keratectomies were performed using each microkeratome on eight freshly enucleated porcine corneas. The freshly cut corneal...
متن کاملEffect of surface passivation on corrosion of a cobalt-chromium dental alloy: surface morphology and chemical composition studies
Abstract Background and Aim: Biocompatibility in some respects depends on the corrosion behavior of dental alloys. The purpose of this study was to investigate the effect of surface passivation of a cobalt chromium alloy on corrosion behavior. Materials and methods: In this experimental study, 20 samples of Flexicast dental alloy were prepared according to ADA97 standard and after casting, t...
متن کاملTumor Associated Mesenchymal Stromal Cells Show Higher Immunosuppressive and Angiogenic Properties Compared to Adipose Derived MSCs
Background: Differentiation, migratory properties and availability of Mesenchymal Stromal Cells (MSC) have become an important part of biomedical research. However, the functional heterogeneity of cells derived from different tissues has hampered providing definitive phenotypic markers for these cells. Objective: To characterize and compare the phenotype and cytokines of adipose derived MSCs (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 17 4 شماره
صفحات -
تاریخ انتشار 2001