Dynamic navicular motion measured using a stretch sensor is different between walking and running, and between over-ground and treadmill conditions

نویسندگان

  • Christian J Barton
  • Simon L Kappel
  • Peter Ahrendt
  • Ole Simonsen
  • Michael S Rathleff
چکیده

BACKGROUND Non-invasive evaluation of in-shoe foot motion has traditionally been difficult. Recently a novel 'stretch-sensor' was proposed as an easy and reliable method to measure dynamic foot (navicular) motion. Further validation of this method is needed to determine how different gait analysis protocols affect dynamic navicular motion. METHODS Potential differences in magnitude and peak velocity of navicular motion using the 'stretch sensor' between (i) barefoot and shod conditions; (ii) overground and treadmill gait; and/or (iii) running and walking were evaluated in 26 healthy participants. Comparisons were made using paired t-tests. RESULTS Magnitude and velocity of navicular motion was not different between barefoot and shod walking on the treadmill. Compared to walking, velocity of navicular motion during running was 59% and 210% higher over-ground (p < 0.0001) and on a treadmill (p < 0.0001) respectively, and magnitude of navicular motion was 23% higher during over-ground running compared to over-ground walking (p = 0.02). Compared to over-ground, magnitude of navicular motion on a treadmill was 21% and 16% greater during walking (p = 0.0004) and running (p = 0003) respectively. Additionally, maximal velocity of navicular motion during treadmill walking was 48% less than walking over-ground (p < 0.0001). CONCLUSION The presence of footwear has minimal impact on navicular motion during walking. Differences in navicular motion between walking and running, and treadmill and over-ground gait highlight the importance of task specificity during gait analysis. Task specificity should be considered during design of future research trials and in clinical practice when measuring navicular motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability and concurrent validity of a novel method allowing for in-shoe measurement of navicular drop

BACKGROUND Increased navicular drop is associated with increased risk of lower extremity overuse injuries and foot orthoses are often prescribed to reduce navicular drop. For laboratory studies, transparent shoes may be used to monitor the effect of orthoses but no clinically feasible methods exist. We have developed a stretch-sensor that allows for in-shoe measurement of navicular drop but the...

متن کامل

Can positional MRI predict dynamic changes in the medial plantar arch? An exploratory pilot study

BACKGROUND Positional MRI (pMRI) allows for three-dimensional visual assessment of navicular position. In this exploratory pilot study pMRI was validated against a stretch sensor device, which measures movement of the medial plantar arch. We hypothesized that a combined pMRI measure incorporating both vertical and medial displacement of the navicular bone induced by loading would be correlated ...

متن کامل

Dynamics of a Running Below-Knee Prosthesis Compared to Those of a Normal Subject

The normal human running has been simulated by two-dimensional biped model with 7 segments. Series of normal running experiments were performed and data of ground reaction forces measured by force plate was analyzed and was fitted to some Fourier series. The model is capable to simulate running for different ages and weights at different running speeds. A proportional derivative control algorit...

متن کامل

The effect of increasing running speed on three-dimensional changes of lower limb joint angles in open motor chain and swing phase

Objective Running is known as one of the most popular sports for which there is no time and space limit. Recently, due to lifestyle changes, the use of treadmills for walking and running has increased. However, the biomechanical differences in coordination between running on a treadmill at different speeds have not been sufficiently addressed. The aim of this study was to investigate the effect...

متن کامل

COMPARING EFFICIENCY OF EXERCISE ON THE TREADMILL AND GROUND ON THE GROUND REACTION FORCES DURING WALKING IN PEOPLE WITH GENU VARUM

Background & Aim: Genu varum is one of the most common abnormalities of the knee joint in which the inner condyles of the femur move away from each other. The aim of the present study was to compare efficiency of exercise on the treadmill and ground on the ground reaction forces during walking in people with genu varum. Material & Methods: The present study was a quasi-experimental and laborat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015