A Biosensor for Fluorescent Determination of ADP with High Time Resolution*
نویسندگان
چکیده
Nearly every cellular process requires the presence of ATP. This is reflected in the vast number of enzymes like kinases or ATP hydrolases, both of which cleave the terminal phosphate from ATP, thereby releasing ADP. Despite the fact that ATP hydrolysis is one of the most fundamental reactions in biological systems, there are only a few methods available for direct measurements of enzymatic-driven ATP conversion. Here we describe the development of a reagentless biosensor for ADP, the common product of all ATPases and kinases, which allows the real-time detection of ADP, produced enzymatically. The biosensor is derived from a bacterial actin homologue, ParM, as protein framework. A single fluorophore (a diethylaminocoumarin), attached to ParM at the edge of the nucleotide binding site, couples ADP binding to a >3.5-fold increase in fluorescence intensity. The labeled ParM variant has high affinity for ADP (0.46 mum) and a fast signal response, controlled by the rate of ADP binding to the sensor (0.65 microm(-1)s(-1)). Amino acids in the active site were mutated to reduce ATP affinity and achieve a >400-fold discrimination against triphosphate binding. A further mutation ensured that the final sensor did not form filaments and, as a consequence, has extremely low ATPase activity. The broad applicability of N-[2-(1-maleimidyl)ethyl]-7-diethylaminocoumarin-3-carboxamide (MDCC)-ParM as a sensitive probe for ADP is demonstrated in real-time kinetic assays on two different ATPases and a protein kinase.
منابع مشابه
A Fluorescent, Reagentless Biosensor for ADP Based on Tetramethylrhodamine-Labeled ParM
Fluorescence assays for ADP detection are of considerable current interest, both in basic research and in drug discovery, as they provide a generic method for measuring the activity of ATPases and kinases. The development of a novel fluorescent biosensor is described that is based on a tetramethylrhodamine-labeled, bacterial actin homologue, ParM. The design of the biosensor takes advantage of ...
متن کاملBiosensor Based on Fluorescent Spherical Resonator Using Polystyrene Microbead
This paper presents an on-chip biosensor using a polystyrene fluorescent microsphere as an optical resonator to enhance the fluorescence emission. The microsphere is attached on the wall of a microchannel in a polydimethylsiloxane (PDMS) optofluidic chip and excited by a focused laser beam using a confocal Raman microscope system. Based on the shift of Whispering Gallery modes (WGMs), this sens...
متن کاملModified Glass Carbon Electrode (GCE) Electropolymerized Polypyrrole Nanofibers with Hemoglobin (Hb) Film as a Unique Biosensor for Nitrite Determination
Abstract: In this study, we were investigated behavior the electrochemical reductionof nitrite at a hemoglobin (Hb) immobilized on glass carbon electrode (GCE) containingpolypyrol nanofiber (ppy) films. Polypyrrole (PPy) nanofibers have been constructed onGCE applying electrochemical technique, and can to deposit diverse polymers onminiaturized electrodes with this commo...
متن کاملDetermination of Aflatoxins B1 and B2 in Powdered Milk Using Modified Liquid Chromatography Method
Background & Aims: In this study, using a liquid-liquid microextraction method for pre-concentration trace amounts of aflatoxins, the amount of Aflatoxins B1 and B2 in powdered milk was determined. Determination of aflatoxins was done by using high-performance liquid chromatography coupled with fluorescent detector. Method: Samples were extracted by immunoaffinity column (IAC) clean-up, and the...
متن کاملDNA Biosensor for Determination of 5-Fluorouracil based on Gold Electrode Modified with Au and Polyaniline Nanoparticles and FFT Square Wave Voltammetry
In the present study, a new biosensor for 5-Fluorouracil was described using modified goldelectrode and Fast Fourier transform square wave voltammetry (FFT SWV). Calf thymus DNAimmobilization was on a gold electrode decorated with polyaniline and gold nanoparticles. Theelectrochemical characteristics of the electrodes were investigated by cyclic voltammetry, andelectroch...
متن کامل