Focal Plane Instrumentation of VERITAS
نویسنده
چکیده
VERITAS is a new atmospheric Cherenkov imaging telescope array to detect very high energy gamma rays above 100 GeV. The array is located in southern Arizona, USA, at an altitude of 1268m above sea level. The array consists of four 12-m telescopes of Davies-Cotton design and structurally resembling the Whipple 10-m telescope. The four focal plane instruments are equipped with high-resolution (499 pixels) fast photo-multiplier-tube (PMT) cameras covering a 3.5 degree field of view with 0.15 degree pixel separation. Light concentrators reduce the dead-space between PMTs to 25% and shield the PMTs from ambient light. The PMTs are connected to high-speed preamplifiers allowing operation at modest anode current and giving good single photoelectron peaks in situ. Electronics in the focus box provides real-time monitoring of the anode currents for each pixel and ambient environmental conditions. A charge injection subsystem installed in the focus box allows daytime testing of the trigger and data acquisition system by injecting pulses of variable amplitude and length directly into the photomultiplier preamplifiers. A brief description of the full VERITAS focal plane instrument is given in this paper.
منابع مشابه
FOCAL POINT AND FOCAL K-PLANE
This paper deals with the basic notions of k-tautimmersions . These notions come from two special cases; that is, tight and taut immersions. Tight and taut based on high and distance functions respectively and their basic notions are normal bundle, endpoint map, focal point, critical normal. We generalize hight and distance functions to cylindrical function and define basic notions of k-taut ...
متن کاملCalibration of optical tweezers with positional detection in the back-focal-plane
We explain and demonstrate a new method of forceand position-calibration for optical tweezers with back-focal-plane photo detection. The method combines power spectral measurements of thermal motion and the response to a sinusoidal motion of a translation stage. It consequently does not use the drag coefficient of the trapped object as an input. Thus, neither the viscosity, nor the size of the ...
متن کاملFast Focal Plane Array Detector and Readout for Pulsed Opto- Thermal Radiometry
Mid-infrared focal plane array spectroscopic or spatial imaging of opto-thermal transient emission is reported. Pulsed near-surface optical heating of arbitrary unprepared room temperature surfaces produce depth-resolved transient thermal emissions in the mid-infrared chemical fingerprint spectral region. Two optical configurations, both offering a significant advance in pulsed photothermal rad...
متن کاملSub-pixel Response Measurement of Near-infrared Sensors
Wide-field survey instruments are used to efficiently observe large regions of the sky. To achieve the necessary field of view, and to provide a higher signal-to-noise ratio for faint sources, many modern instruments are undersampled. However, precision photometry with undersampled imagers requires a detailed understanding of the sensitivity variations on a scale much smaller than a pixel. To a...
متن کاملAberration corrected TEM: current status and future prospects
Aberration correction leads to a substantial improvement in the interpretable resolution of Transmission Electron Microscopes. Electron optical correctors based on two strong hexapole elements linked through a round lens transfer doublet enables direct correction of all axial aberrations to third order. Subsequent, indirect computational analysis of a focal or tilt series of images offers the p...
متن کامل