Optical Imaging with a Cathepsin B Activated Probe for the Enhanced Detection of Esophageal Adenocarcinoma by Dual Channel Fluorescent Upper GI Endoscopy
نویسندگان
چکیده
Despite significant advances in diagnosis and treatment, the prognosis of esophageal adenocarcinoma remains poor highlighting the importance of early detection. Although white light (WL) upper endoscopy can be used for screening of the esophagus, it has limited sensitivity for early stage disease. Thus, development of new imaging technology to improve the diagnostic capabilities of upper GI endoscopy for early detection of esophageal adenocarcinoma is an important unmet need. The goal of this study was to develop a method for the detection of malignant lesions in the esophagus using WL upper endoscopy combined with near infrared (NIR) imaging with a protease activatable probe (Prosense750) selective for cathepsin B (CTSB). An orthotopic murine model for distal esophageal adenocarcinoma was generated through the implantation of OE-33 and OE-19 human esophageal adenocarcinoma lines in immunocompromised mice. The mice were imaged simultaneously for WL and NIR signal using a custom-built dual channel upper GI endoscope. The presence of tumor was confirmed by histology and target to background ratios (TBR) were compared for both WL and NIR imaging. NIR imaging with ProSense750 significantly improved upon the TBRs of esophageal tumor foci, with a TBR of 3.64±0.14 and 4.50±0.11 for the OE-33 and OE-19 tumors respectively, compared to 0.88±0.04 and 0.81±0.02 TBR for WL imaging. The combination of protease probes with novel imaging devices has the potential to improve esophageal tumor detection by fluorescently highlighting neoplastic regions.
منابع مشابه
Detection of Esophageal Squamous Cell Carcinoma by Cathepsin B Activity in Nude Mice
BACKGROUND AND OBJECTIVE Despite great progress in treatment, the prognosis for patients with esophageal squamous cell carcinoma (ESCC) remains poor, highlighting the importance of early detection. Although upper endoscopy can be used for the screening of esophagus, it has limited sensitivity for early stage disease. Thus, development of new diagnosis approach to improve diagnostic capabilities...
متن کاملRecent Advances in Molecular Imaging of Premalignant Gastrointestinal Lesions and Future Application for Early Detection of Barrett Esophagus
Recent advances in optical molecular imaging allow identification of morphologic and biochemical changes in tissues associated with gastrointestinal (GI) premalignant lesions earlier and in real-time. This focused review series introduces high-resolution imaging modalities that are being evaluated preclinically and clinically for the detection of early GI cancers, especially Barrett esophagus a...
متن کاملComment on "Medical Management and Outcome of Paraquat Poisoning in Ahvaz, Iran: A Hospital-Based Study"
Dear editor, We read the recent article of Rahmani et al entitled "Medical Management and Outcome of Paraquat Poisoning in Ahvaz, Iran: A Hospital-Based Study" in your journal (1). In their study they performed upper gastrointestinal (GI) endoscopy as a routine for all paraquat poisoned patients, because they considered paraquat a caustic agent and that it may cause severe mucosal injuries in e...
متن کاملPrevalence of helicobacter pylori in patients undergoing upper GI endoscopy in hospital No 1 Kerman university of medical sciences
Prevalence of helicobacter pylori was evaluated by urease test in 513 patients undergoing GI endoscopy, in hospital No1 Kerman university of medical sciences and health services from June 1992 through April 1993. H. Pylori was detected in 56.9℅ of tested samples by urease test. There was no significant correlation with sex, age and cigarette smoking. Prevalence of H.pylori was 16℅ in control gr...
متن کاملUse of i-scan Endoscopic Image Enhancement Technology in Clinical Practice to Assist in Diagnostic and Therapeutic Endoscopy: A Case Series and Review of the Literature
Background. i-scan is a software-driven technology that allows modifications of sharpness, hue, and contrast to enhance mucosal imaging. It uses postimage acquisition software with real-time mapping technology embedded in the endoscopic processor. Aims. To review applications of i-scan technology in clinical endoscopic practice. Methods. This is a case series of 20 consecutive patients who unde...
متن کامل