Comparison between resting energy expenditure measured by indirect calorimetry and metabolic rate estimate based on Harris-Benedict equation in septic patients

نویسندگان

  • Jiro Kamiyama
  • Tomonori Takazawa
  • Akihiro Yanagisawa
  • Masafumi Kanamoto
  • Masaru Tobe
  • Shigeru Saito
چکیده

Background: Providing an adequate caloric intake is essential for improving clinical outcomes, because inadequate nutrition induces several problems. Previous studies have shown that energy expenditure calculated by classical prediction equations, such as the Harris-Benedict equation (HBE), is greater than the measured resting energy expenditure (REE). To compensate for this discrepancy, additional factors, such as a stress factor, are often used to rescale the value. However, the numerical value of the stress factor, particularly in septic patients, is unknown. Indirect calorimetry (IC) enables to the real-time measurement of REE at the bedside. We hypothesized that the stress factor could decrease over the time course of recovery in septic patients. To test this hypothesis, we measured the REE of septic patients hospitalized in our ICU throughout their intubation period. Methods: This single-center retrospective study was conducted to compare resting REE measured by IC and the estimated energy expenditure in adult septic patients. Basal metabolic rate (BMR) was estimated by the HBE. Chronological changes in the ratio of measured REE to BMR were analyzed to estimate the stress factor. Results: A total of 47 patients with sepsis were included in this study. We found that REE/BMR in the septic patients was in the range of 1.07 to 1.11. Moreover, the estimated stress factor did not change over time during the intubation period. REE/BMR did not depend on the number of sedatives administered. Both sequential organ failure assessment (SOFA) scores and blood concentrations of C-reactive protein (CRP) decreased over time. Respiratory quotient (RQ) on the last intubation day was greater than that on the first day. Conclusions: The REE measured by IC in sedated septic patients was approximately 1.1 times greater than BMR. The ratio of measured REE to BMR does not change with resolution of the illness. This result was likely caused by the concomitant increase in energy intake and improvement in patient general condition at this time. These findings may contribute to better nutrition control in ICU-admitted septic patients. Correspondence to: Dr. Tomonori Takazawa, Intensive Care Unit, Gunma University Hospital, Japan, Tel: +81-27-220-8693; Fax: +81-27-220-8692; E-mail: [email protected]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Harris Benedict and Mifflin-ST Jeor equations with indirect calorimetry in evaluating resting energy expenditure.

BACKGROUND An understanding of energy expenditure in hospitalized patients is necessary to determine optimal energy supply. The metabolic rate can be measured or estimated by equations, but estimation is by far the most common method. AIM This study tests the degree of agreement between measured resting energy expenditure by indirect calorimetry and predicted resting energy expenditure by Har...

متن کامل

Comparison of measured versus predicted energy requirements in critically ill cancer patients.

BACKGROUND Accurate determination of caloric requirements is essential to avoid feeding-associated complications in critically ill patients. METHODS In critically ill cancer patients we compared the measured and estimated resting energy expenditures. All patients admitted to the oncology intensive care unit between March 2004 and July 2005 were considered for inclusion. For those patients enr...

متن کامل

Validation of a predictive method for an accurate assessment of resting energy expenditure in medical mechanically ventilated patients.

OBJECTIVE Use comparison with indirect calorimetry to confirm the ability of our previously described equation to predict resting energy expenditure in mechanically ventilated patients. DESIGN Prospective, validation study. SETTING Eighteen-bed, medical intensive care unit at a teaching hospital. PATIENTS All adult patients intubated >24 hrs were assessed for eligibility. Exclusion criter...

متن کامل

Are prediction equations reliable for estimating resting energy expenditure in chronic kidney disease patients?

BACKGROUND The determination of resting energy expenditure (REE) is the primary step for estimating the energy requirement of an individual. Although numerous equations have been formulated for predicting metabolic rates, there is a lack of studies addressing the reliability of those equations in chronic kidney disease (CKD). Thus, the aim of this study was to evaluate whether the main equation...

متن کامل

The agreement between measured and predicted resting energy expenditure in patients with pancreatic cancer: a pilot study.

OBJECTIVE To compare measured resting energy expenditure to resting energy expenditure predicted from eight published prediction equations in a sample of patients with pancreatic cancer. DESIGN Cross-sectional study. SETTING Ambulatory patients of a tertiary private hospital. PARTICIPANTS Eight patients with pancreatic cancer (5 males, 3 females; age: 62.0+/- 5.2 years; BMI: 24.4+/- 3.2 k...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016