Parallel picoliter rt-PCR assays using microfluidics.
نویسندگان
چکیده
The development of microfluidic tools for high-throughput nucleic acid analysis has become a burgeoning area of research in the post-genome era. Here, we have developed a microfluidic chip to perform 72 parallel 450-pL RT-PCRs. We took advantage of Taqman hydrolysis probe chemistry to detect RNA templates as low as 34 copies. The device and method presented here may enable highly parallel single cell gene expression analysis.
منابع مشابه
On-chip, real-time, single-copy polymerase chain reaction in picoliter droplets.
The first lab-on-chip system for picoliter droplet generation and PCR amplification with real-time fluorescence detection has performed PCR in isolated droplets at volumes 106 smaller than commercial real-time PCR instruments. The system utilized a shearing T-junction in a silicon device to generate a stream of monodisperse picoliter droplets that were isolated from the microfluidic channel wal...
متن کاملValidation of oligonucleotide microarray data using microfluidic low-density arrays: a new statistical method to normalize real-time RT-PCR data.
Profiling studies using microarrays to measure messenger RNA (mRNA) expression frequently identify long lists of differentially expressed genes. Differential expression is often validated using real-time reverse transcription PCR (RT-PCR) assays. In conventional real-time RT-PCR assays, expression is normalized to a control, or housekeeping gene. However, no single housekeeping gene can be used...
متن کاملOn-chip single-copy real-time reverse-transcription PCR in isolated picoliter droplets.
The first lab-on-chip system for picoliter droplet generation and RNA isolation, followed by reverse transcription, and PCR amplification with real-time fluorescence detection in the trapped droplets has been developed. The system utilized a shearing T-junction in a fused-silica device to generate a stream of monodisperse picoliter-scale droplets that were isolated from the microfluidic channel...
متن کاملA novel picoliter droplet array for parallel real-time polymerase chain reaction based on double-inkjet printing.
We developed and characterized a novel picoliter droplet-in-oil array generated by a double-inkjet printing method on a uniform hydrophobic silicon chip specifically designed for quantitative polymerase chain reaction (qPCR) analysis. Double-inkjet printing was proposed to efficiently address the evaporation issues of picoliter droplets during array generation on a planar substrate without the ...
متن کاملDroplet microfluidics for single cell and nucleic acid analysis
...................................................................................................................... 3 List of publications and manuscript ......................................................................... 9 Contributions to the publications ........................................................................... 10 Table of contents ....................................
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 78 3 شماره
صفحات -
تاریخ انتشار 2006