Effects of Epicardial and Endocardial Cardiac Resynchronization Therapy on Coronary Flow: Insights From Wave Intensity Analysis.
نویسندگان
چکیده
BACKGROUND The increase in global coronary flow seen with conventional biventricular pacing is mediated by an increase in the dominant backward expansion wave (BEW). Little is known about the determinants of flow in the left-sided epicardial coronary arteries beyond this or the effect of endocardial pacing stimulation on coronary physiology. METHODS AND RESULTS Eleven patients with a chronically implanted biventricular pacemaker underwent an acute hemodynamic and electrophysiological study. Five of 11 patients also took part in a left ventricular endocardial pacing protocol at the same time. Conventional biventricular pacing, delivered epicardially from the coronary sinus, resulted in a 9% increase in flow (average peak velocity) in the left anterior descending artery (LAD), mediated by a 13% increase in the area under the BEW (P=0.004). Endocardial pacing resulted in a 27% increase in LAD flow, mediated by a 112% increase in the area under the forward compression wave (FCW) and a 43% increase in the area under the BEW (P=0.048 and P=0.036, respectively). There were no significant changes in circumflex parameters. Conventional biventricular pacing resulted in homogenization of timing of coronary flow compared with baseline (mean difference in time to peak in the LAD versus circumflex artery: FCW 39 ms [baseline] versus 3 ms [conventional biventricular pacing], P=0.008; BEW 47 ms [baseline] versus 8 ms [conventional biventricular pacing], P=0.004). CONCLUSIONS Epicardial and endocardial pacing result in increased coronary flow in the left anterior descending artery and homogenization of the timing of waves that determine flow in the LAD and the circumflex artery. The increase in both the FCW and the BEW with endocardial pacing may be the result of a more physiological activation pattern than that of epicardial pacing, which resulted in an increase of only the BEW.
منابع مشابه
Comparison of the Effects of Epicardial and Endocardial Cardiac Resynchronization Therapy on Transmural Dispersion of Repolarization.
BACKGROUND Despite significant improvements in cardiac output and functional capacity with cardiac resynchronization therapy (CRT), incidence of sudden cardiac death still remains high. Reversal of physiological myocardial activation sequence during epicardial pacing increases the transmural dispersion of repolarization (TDR). The aim of this study was to compare the effects of endocardial and ...
متن کاملLeft ventricular endocardial or triventricular pacing to optimize cardiac resynchronization therapy in a chronic canine model of ischemic heart failure.
Cardiac resynchronization therapy (CRT) is a proven treatment for heart failure but ~30% of patients appear to not benefit from the therapy. Left ventricular (LV) endocardial and multisite epicardial [triventricular (TriV)] pacing have been proposed as alternatives to traditional LV transvenous epicardial pacing, but no study has directly compared the hemodynamic effects of these approaches. Le...
متن کاملEndocardial left ventricular pacing improves cardiac resynchronization therapy in chronic asynchronous infarction and heart failure models.
BACKGROUND Studies in canine hearts with acute left bundle branch block (LBBB) showed that endocardial left ventricular (LV) pacing improves the efficacy of cardiac resynchronization therapy (CRT) compared with conventional epicardial LV pacing. The present study explores the efficacy of endocardial CRT in more compromised hearts and the mechanisms of such beneficial effects. METHODS AND RESU...
متن کاملA comparison of left ventricular endocardial, multisite, and multipolar epicardial cardiac resynchronization: an acute haemodynamic and electroanatomical study.
AIMS Alternative forms of cardiac resynchronization therapy (CRT), including biventricular endocardial (BV-Endo) and multisite epicardial pacing (MSP), have been developed to improve response. It is unclear which form of stimulation is optimal. We aimed to compare the acute haemodynamic response (AHR) and electrophysiological effects of BV-Endo with MSP via two separate coronary sinus (CS) lead...
متن کاملOptimal left ventricular endocardial pacing sites for cardiac resynchronization therapy in patients with ischemic cardiomyopathy.
OBJECTIVES We sought to investigate the impact of left ventricular (LV) pacing site on mechanical response to cardiac resynchronization therapy (CRT) in patients with ischemic cardiomyopathy (ICM). BACKGROUND CRT reduces morbidity and mortality in patients with dyssynchronous LV failure; however, variability in response, particularly in ICM patients, poses ongoing challenges. Endocardial bive...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Heart Association
دوره 4 12 شماره
صفحات -
تاریخ انتشار 2015