Intracoronary beta-irradiation with a rhenium-188-filled balloon catheter: a randomized trial in patients with de novo and restenotic lesions.

نویسندگان

  • Martin Höher
  • Jochen Wöhrle
  • Markus Wohlfrom
  • Joachim Kamenz
  • Thorsten Nusser
  • Olaf C Grebe
  • Hartmut Hanke
  • Matthias Kochs
  • Sven N Reske
  • Vinzenz Hombach
  • Jörg Kotzerke
چکیده

BACKGROUND Restenosis requiring reintervention is the main limitation of coronary angioplasty. Intracoronary irradiation reduces neointimal proliferation. We studied the efficacy of a self-centering liquid rhenium-188-filled balloon catheter for coronary beta-brachytherapy. METHODS AND RESULTS After successful coronary angioplasty with or without stenting, 225 patients (71% de novo lesions) were randomly assigned to receive 22.5 Gy intravascular beta-irradiation in 0.5-mm tissue depth (n=113) or to receive no additional intervention (n=112). Clinical and procedural data did not differ between the groups except a higher rate of stenting in the control group (63%) compared with the rhenium-188 group (45%, P<0.02). After 6 months of follow-up, late loss was significantly lower in the irradiated group compared with the control group, both of the target lesion (0.11+/-0.54 versus 0.69+/-0.81 mm, P<0.0001) and of the total segment (0.22+/-0.67 versus 0.70+/-0.82 mm, P<0.0001). This was also evident in the subgroup of patients with de novo lesions and independent from stenting. Binary restenosis rates were significantly lower at the target lesion (6.3% versus 27.5%, P<0.0001) and of the total segment (12.6% versus 28.6%, P<0.007) after rhenium-188 brachytherapy compared with the control group. Target vessel revascularization rate was significantly lower in the rhenium-188 (6.3%) compared with the control group (19.8%, P=0.006). CONCLUSIONS Intracoronary beta-brachytherapy with a rhenium-188 liquid-filled balloon is safe and efficiently reduces restenosis and revascularization rates after coronary angioplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of diffuse in-stent restenosis with rotational atherectomy followed by radiation therapy with a rhenium-188-mercaptoacetyltriglycine-filled balloon.

OBJECTIVES This study was done to evaluate the feasibility and efficacy of beta-radiation therapy with a rhenium-188-mercaptoacetyltriglycine ((188)Re-MAG(3))-filled balloon after rotational atherectomy for diffuse in-stent restenosis (ISR). BACKGROUND Rotational atherectomy has been shown to be safe and efficient for the treatment of ISR, but the recurrence rate is still high. Intracoronary ...

متن کامل

The Proliferation REduction with Vascular ENergy Trial (PREVENT)

PREVENT was the first prospective, randomized placebo-controlled study of intracoronary beta radiotherapy with 32P. A total of 105 patients with de novo or restenotic lesions, treated by stenting or balloon angioplasty, received 0 (control), 16, 20, or 24 Gy to a depth of 1 mm beyond the lumen surface. Rates of restenosis (50% diameter stenosis or more) were significantly lower in radiotherapy ...

متن کامل

Inhibition of Restenosis With b-Emitting Radiotherapy

Background—Intracoronary gand b-radiation have reduced restenosis in animal models. In the clinical setting, the effectiveness of b-emitters has not been studied in a broad spectrum of patients, particularly those receiving stents. Methods and Results—A prospective, randomized, sham-controlled study of intracoronary radiotherapy with the b-emitting P source wire, using a centering catheter and ...

متن کامل

Different radiosensitivity of smooth muscle cells and endothelial cells in vitro as demonstrated by irradiation from a Re-188 filled balloon catheter.

There is an increasing interest in irradiation to control restenosis after balloon angioplasty by an internal radioactive source. Differences in radiosensitivity of the predominant cells of the human coronary artery (i.e. endothelial cells (HCAEC), smooth muscle cells from the media (HCMSMC) and from plaque material (HCPSMC), are issues of controversal discussion. Therefore, we investigated the...

متن کامل

Reno, a European postmarket surveillance registry, confirms effectiveness of coronary brachytherapy in routine clinical practice.

PURPOSE To assess, by a European registry trial, the clinical event rate in patients with discrete stenotic lesions of coronary arteries (de novo or restenotic) in single or multiple vessels (native or bypass grafts) treated with beta-radiation. MATERIALS AND METHODS Between April 1999 and September 2000, 1098 consecutive patients treated in 46 centers in Europe and the Middle East with the N...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 107 24  شماره 

صفحات  -

تاریخ انتشار 2003