Pulmonary arterial morphometry from microfocal X-ray computed tomography.

نویسندگان

  • K L Karau
  • R C Molthen
  • A Dhyani
  • S T Haworth
  • C C Hanger
  • D L Roerig
  • R H Johnson
  • C A Dawson
چکیده

The objective of this study was to develop an X-ray computed tomographic method for pulmonary arterial morphometry. The lungs were removed from a rat, and the pulmonary arterial tree was filled with perfluorooctyl bromide to enhance X-ray absorbance. At each of four pulmonary arterial pressures (30, 21, 12, and 5.4 mmHg), the lungs were rotated within the cone of the X-ray beam that was projected from a microfocal X-ray source onto an image intensifier, and 360 images were obtained at 1 degrees increments. The three-dimensional image volumes were reconstructed with isotropic resolution with the use of a cone beam reconstruction algorithm. The luminal diameter and distance from the inlet artery were measured for the main trunk, its immediate branches, and several minor trunks. These data revealed a self-consistent tree structure wherein the portion of the tree downstream from any vessel of a given diameter has a similar structure. Self-consistency allows the entire tree structure to be characterized by measuring the dimensions of only the vessels comprising the main trunk of the tree and its immediate branches. An approach for taking advantage of this property to parameterize the morphometry and distensibility of the pulmonary arterial tree is developed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative Methodology Three-dimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography

Litzlbauer, Horst Detlef, Christoph Neuhaeuser, Alexander Moell, Susanne Greschus, Andreas Breithecker, Folker Ernst Franke, Wolfgang Kummer, and Wigbert Stephan Rau. Threedimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography. Am J Physiol Lung Cell Mol Physiol 291: L535–L545, 2006. First published May 5, 2006; doi:10.1152/ajplung.00088.2005....

متن کامل

Three-dimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography.

We evaluated microfocal X-ray-computed tomography (micro-CT) as a method to visualize lung architecture two and three dimensionally and to obtain morphometric data. Inflated porcine lungs were fixed by formaldehyde ventilation. Tissue samples (8-mm diameter, 10-mm height) were stained with osmium tetroxide, and 400 projection images (1,024 x 1,024 pixel) were obtained. Continuous isometric micr...

متن کامل

Three-dimensional visualization and morphometry of small airways from microfocal X-ray computed tomography.

Physiological morphometry is a critical factor in the flow dynamics in small airways. In this study, we visualized and analyzed the three-dimensional structure of the small airways without dehydration and fixation. We developed a two-step method to visualize small airways in detail by staining the lung tissue with a radiopaque solution and then visualizing the tissue with a cone-beam microfocal...

متن کامل

Quantitative models of the rat pulmonary arterial tree morphometry applied to hypoxia-induced arterial remodeling.

Little is known about the constituent hemodynamic consequences of structural changes that occur in the pulmonary arteries during the onset and progression of pulmonary arterial remodeling. Many disease processes are known to be responsible for vascular remodeling that leads to pulmonary arterial hypertension, cor pulmonale, and death. Histology has been the primary tool for evaluating pulmonary...

متن کامل

Microfocal X-ray CT imaging and pulmonary arterial distensibility in excised rat lungs.

The objective of this study was to develop an X-ray computed tomographic method for measuring pulmonary arterial dimensions and locations within the intact rat lung. Lungs were removed from rats and their pulmonary arterial trees were filled with perfluorooctyl bromide to enhance X-ray absorbance. The lungs were rotated within the cone of the X-ray beam projected from a microfocal X-ray source ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 281 6  شماره 

صفحات  -

تاریخ انتشار 2001