Review of transcranial Doppler ultrasound to detect microemboli during orthopedic surgery.
نویسندگان
چکیده
Transcranial Doppler ultrasonography has been used to detect microemboli in the middle cerebral artery during orthopedic surgery. We conducted a comprehensive systematic literature review of transcranial Doppler ultrasonography in orthopedic surgery to evaluate its status in this setting. Fourteen studies were selected for qualitative analysis. The highest number of patients studied was 45; emboli were detected in all studies, occurring in 20%-100% of patients. Most embolic counts were below 10, but some high counts were noted. No study reported all the technical parameters of the transcranial Doppler ultrasonography. All studies assessed neurologic status, and 6 studies evaluated cognitive function postoperatively. No study identified an association between postoperative cognitive function and embolic count. Six studies sought the presence of right-to-left shunts.
منابع مشابه
The impact of microemboli during cardiopulmonary bypass on neuropsychological functioning.
BACKGROUND AND PURPOSE Microemboli have been implicated in the etiology of neuropsychological deficits after cardiopulmonary bypass. This study examined the incidence of high-intensity transcranial signals (microemboli) and their relation to changes in neuropsychological performance after surgery. METHODS Transcranial Doppler ultrasonography was used to measure middle cerebral artery blood fl...
متن کاملDetection of Middle Cerebral Emboli During Coronary Artery Bypass Surgery Using Transcranial Doppler Sonography
Detection of Middle Cerebral Emboli During Coronary Artery Bypass Surgery Using Transcranial Doppler Sonography To the Editor: Spencer et al recently described the use of transcranial Doppler sonography to record the passage of emboli through the middle cerebral artery (MCA) during carotid endarterectomy. They recorded transient signals at the time of releasing common carotid cross clamps and i...
متن کاملDetection of Doppler Microembolic Signals Using High Order Statistics
Robust detection of the smallest circulating cerebral microemboli is an efficient way of preventing strokes, which is second cause of mortality worldwide. Transcranial Doppler ultrasound is widely considered the most convenient system for the detection of microemboli. The most common standard detection is achieved through the Doppler energy signal and depends on an empirically set constant thre...
متن کاملPii: S0301-5629(01)00486-0
Difficulties in location of transcranial ultrasound (US) windows and blood flow in cerebral vessels, and unambiguous detection of microemboli, have limited expansion of transcranial Doppler US. We developed a new transcranial Doppler modality, power M-mode Doppler (PMD), for addressing these issues. A 2-MHz digital Doppler (Spencer Technologies TCD100M) having 33 sample gates placed with 2-mm s...
متن کاملAbsence of microemboli on transcranial Doppler identifies low-risk patients with asymptomatic carotid stenosis.
BACKGROUND AND PURPOSE Carotid endarterectomy clearly benefits patients with symptomatic severe stenosis (SCS), but the risk of stroke is so low for asymptomatic patients (ACS) that the number needed to treat is very high. We studied transcranial Doppler (TCD) embolus detection as a method for identifying patients at higher risk who would have a lower number needed to treat. METHODS Patients ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 35 10 شماره
صفحات -
تاریخ انتشار 2014