Influence of different positions on hemodynamics derived from noninvasive transcutaneous Doppler ultrasound
نویسندگان
چکیده
A proper alignment of the ultrasound beam to the aortic or pulmonary outflow tracts is essential to acquire accurate signals. This study aimed to investigate the influence of different positions on the acquisition of Doppler signals using a noninvasive transcutaneous Doppler ultrasound. This was a prospective observational crossover study. Two operators performed hemodynamics measurements on each subject in supine, sitting, semirecumbent, passive leg raising (PLR) 20°, and PLR 60° positions using both aortic and pulmonary approaches. All Doppler flow profile images were assessed using the Fremantle and Prince of Wales Hospital criteria. Time required to obtain Doppler signals was recorded. A total of 60 subjects (50% males) aged 18-60 years old were investigated. In both sitting and semirecumbent positions, aortic stroke volume indexes (SVIs) and cardiac indexes (CIs) were significantly lower than those in the other three positions while the pulmonary CIs were comparable to that in the supine position. In the sitting position, the aortic signal qualities were lower and the time to obtain the pulmonary Doppler signals was prolonged. Instead, the signal quality and the time to obtain the Doppler signals in the semirecumbent position were similar to those in the other three positions using the pulmonary approach. PLR did not cause a significant increase in SVI regardless of the degree of leg elevation. These data show that it is feasible to perform the noninvasive transcutaneous Doppler ultrasound using the pulmonary approach in the semirecumbent position for patients unable to maintain the supine position. The aortic approach in the sitting and semirecumbent positions is not suitable as it is not sufficiently reliable.
منابع مشابه
Noninvasive estimation of intracranial pressure using TCD
Usefulness of transcranial Doppler-derived cerebral hemodynamic parameters in the noninvasive assessment of intracranial pressure. Author Wakerley BR1, Kusuma Y, Yeo LL, Liang S, Kumar K, Sharma AK, Sharma VK. Content/Summary Abstract BACKGROUND: Transcranial Doppler (TCD) ultrasonography is a noninvasive bedside tool that can evaluate cerebral blood flow hemodynamics in major intracranial arte...
متن کاملمقایسه سرعت جریان خون شریان مغزی میانی در زنان حامله پره اکلامپتیک و زنان حامله نرمال با استفاده از داپلرترانس کرانیال
Background & Aim: Preeclampsia is the major cause of maternal and perinatal morbidity and mortality. Transcranial Doppler(TCD) as a noninvasive procedure is used to assess hemodynamic changes in middle cerebral artery(MCA). Knowing the influence of normal pregnancy and preeclampsia on brain hemodynamics is essential for proper management of anesthesia, labor and vasoactive drug usage in the...
متن کاملمقایسه وازوموتور راکتیویتی مغز در بیماران دیابت قندی و بدون دیابت قندی
Background and Aim: Diabetes Mellitus (DM) increases the risk of ischemic cerebrovascular diseases two- to four folds as compared to people without diabetes. Macrovascular disease is the leading cause of death among patients with diabetes mellitus. Transcranial Doppler (TCD) is a noninvasive procedure used to assess the hemodynamic changes in Middle Cerebral Artery (MCA). Knowing the influe...
متن کاملA Digital Multigate Doppler Method for High Frequency Ultrasound
Noninvasive visualization of blood flow with high frequency Doppler ultrasound has been extensively used to assess the morphology and hemodynamics of the microcirculation. A completely digital implementation of multigate pulsed-wave (PW) Doppler method was proposed in this paper for high frequency ultrasound applications. Analog mixer was eliminated by a digital demodulator and the same data ac...
متن کاملPulmonary Vascular Bed by Echo
patterns in blood vessels with the directional ultrasonic Doppler technique through a transcutaneous approach. Jap Circ J 37: 735, 1973 37. Kalmanson D, Aigueperse J, Veyrat C, Cornec C, Chiche P: Noninvasive technique for diagnosing congenital and acquired ventricular septal defects using directional Doppler ultrasound. Correlations with phasic flow velocity patterns of the shunt. Br Heart J 3...
متن کامل