A moiré deflectometer for antimatter
نویسندگان
چکیده
The precise measurement of forces is one way to obtain deep insight into the fundamental interactions present in nature. In the context of neutral antimatter, the gravitational interaction is of high interest, potentially revealing new forces that violate the weak equivalence principle. Here we report on a successful extension of a tool from atom optics--the moiré deflectometer--for a measurement of the acceleration of slow antiprotons. The setup consists of two identical transmission gratings and a spatially resolving emulsion detector for antiproton annihilations. Absolute referencing of the observed antimatter pattern with a photon pattern experiencing no deflection allows the direct inference of forces present. The concept is also straightforwardly applicable to antihydrogen measurements as pursued by the AEgIS collaboration. The combination of these very different techniques from high energy and atomic physics opens a very promising route to the direct detection of the gravitational acceleration of neutral antimatter.
منابع مشابه
Development of nuclear emulsions with 1 μm spatial resolution for the AEgIS experiment
The main goal of the AEgIS experiment at CERN is to test the weak equivalence principle for antimatter. We will measure the Earth's gravitational acceleration g with antihydrogen atoms being launched in a horizontal vacuum tube and traversing a moiré deflectometer. We intend to use a position sensitive device made of nuclear emulsions (combined with a time-of-flight detector such as silicon μ s...
متن کاملUse of a Two-Channel Moiré Wavefront Sensor for Measuring Topological Charge Sign of the Vortex Beam and Investigation of Its Change Due to an Odd Number of Reflections
One of the solutions of the Helmholtz equation is the vortex beams. In the recent decades, production and applications of these types of beams have found serious attentions. Determination of the vortex beam topological charge and its sign are very important issues. Odd number of reflections of the vortex beam changes its vorticity. In this paper, we have used a q-plate to generate a vortex beam...
متن کاملRemote Bridge Deflection Measurement Using an Advanced Video Deflectometer and Actively Illuminated LED Targets
An advanced video deflectometer using actively illuminated LED targets is proposed for remote, real-time measurement of bridge deflection. The system configuration, fundamental principles, and measuring procedures of the video deflectometer are first described. To address the challenge of remote and accurate deflection measurement of large engineering structures without being affected by ambien...
متن کاملBeamformed Flow-Acoustic Correlations in a Supersonic Jet
An experimental study of simultaneousmultipoint measurements in the flowfield and acoustic field of aMach 1.75 cold-air jet is presented. A series of four optical-deflectometer probes measured turbulent fluctuations in or near the jet flow, and eight microphones recorded the far-field pressure in the direction of peak emission. The correlation methodology involves the coherence between the dela...
متن کاملDesign and Construction of a Seismometer Based on the Moiré Technique: Detailed Theoretical Analysis, Experimental Apparatus, and Primary Results
We have built a vertical seismometer that works based on the moiré technique. One grating is attached to the suspended mass and one to the frame of the instrument. The two gratings are in relative motion, and the resulting moiré pattern magnifies this motion. The intensity of a light beam passing through the moving moiré fringes changes with time, and a light detecting syst...
متن کامل