Contemporary Reviews in Interventional Cardiology Edge Effect From Drug-Eluting Stents as Assessed With Serial Intravascular Ultrasound A Systematic Review

نویسندگان

  • Kohei Wakabayashi
  • Ron Waksman
  • Neil J. Weissman
چکیده

Several studies have demonstrated effective reduction of intimal hyperplasia within a drug-eluting stent (DES) when compared with a bare metal stent (BMS), thereby resulting in a lower incidence of target lesion revascularization.1–3 Restenosis at the stent edges, however, is not appreciably reduced by DES. Thus, to understand stent edge effect in DES, it is important to improve the efficacy of this technology. The concern that stent edge effects alter intimal hyperplasia in the stent but not at the edges has existed for many years, and often is described as the “candy wrapper phenomenon.” This phenomenon was first described in radioactive stents4,5 and is due to local inhibition of intimal growth and endothelial healing6 only within the stent. Many DES trials, therefore, sought to better understand the edge effect using intravascular ultrasound (IVUS) to assess the vessel response post stent implantation. Many studies have documented DES edge effect in olderand newer-generation DES. One challenge facing IVUS studies that assess DES edge effect is a high degree of patient-to-patient variability, along with potential variability among the different DES types. Because of these variables and the relatively small size of most sequential IVUS studies, there is no general consensus regarding stent edge effect in DES. We therefore reviewed the literature to find common findings and tendency. This review focused on 4 DES types approved by the United States Food and Drug Administration: the Cypher sirolimus-eluting stent (SES) (Cordis), the Taxus paclitaxel-eluting stent (PES) (Boston Scientific), the Endeavor zotarolimus-eluting stent (ZES) (Medtronic CardioVascular Inc.), and the XIENCE V everolimus-eluting stent (EES) (Abbott Vascular).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contemporary Reviews in Interventional Cardiology Advances in Intravascular Imaging

This review updates the role of various intravascular imaging techniques (1) in the detection of vulnerable plaque and (2) during percutaneous coronary intervention (PCI), especially drug-eluting stent (DES) implantation and follow-up—including intravascular ultrasound (IVUS), virtual histology (VH-IVUS) and integrated backscatter (IBIVUS), optical coherent tomography (OCT), near-infrared (NIR)...

متن کامل

Almanac 2012: Interventional cardiology.

The field of interventional cardiology continues to progress quickly. The efficacy of percutaneous interventions with newer generation drug-eluting stents has advanced a lot over the last decade. This improvement in stent performance has broadened the level of indication towards more complex interventions such as left main and multi- vessel PCI. Major improvements continue in the field of medic...

متن کامل

Mechanisms, pathophysiology, and clinical aspects of incomplete stent apposition.

Incomplete stent apposition (ISA) is characterized by the lack of contact of at least 1 stent strut with the vessel wall in a segment not overlying a side branch; it is more commonly found in drug-eluting stents than bare-metal stents. The accurate diagnosis of ISA, initially only possible with intravascular ultrasound, can currently be performed with higher accuracy by optical coherence tomogr...

متن کامل

Impact of arterial injury on neointimal hyperplasia after implantation of drug-eluting stents in coronary arteries: an intravascular ultrasound study.

AIMS We investigated the impact of arterial injury on neointimal hyperplasia following implantation of drug-eluting stents (DES). METHODS AND RESULTS A total of 196 patients with 223 segments (sirolimus-eluting stents [SES]: 104, paclitaxel-eluting stents [PES]: 119) underwent intravascular ultrasound eight months after DES implantation. Arterial injury was defined as the balloon-to-artery ra...

متن کامل

Plasma brain natriuretic peptide-guided therapy not yet justified.

1. Iakovow I, Schmidt T, Bonizzoni E, et al. Incidence, predictors and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 2005;293:2126–30. 2. Kuchulakanti PK, Chu WW, Torguson R, et al. Correlates and long-term outcomes of angiographically proven stent thrombosis with sirolimus and paclitaxel-eluting stents. Circulation 2006;113; 1108 –13. 3. Alfonso F, Suarez A, ...