Correlation of airway hyper-responsiveness with obstructive spirometric indices and FEV(1) > 90% of predicted.
نویسندگان
چکیده
BACKGROUND Current published guidelines on spirometry interpretation suggest an elevated FVC and FEV(1) > 100% of predicted with an obstructive ratio may represent a physiological variant. There is minimal evidence whether this finding can be indicative of symptomatic airways obstruction. METHODS Pulmonary function testing databases for a 4-year period were retrospectively reviewed. All technically adequate spirometry studies were included, based on these criteria: FEV(1) > 90% of predicted, and FEV(1)/FVC below the lower limit of normal, based on 95th percentile confidence intervals. Clinical indications for testing were noted. Testing for post-bronchodilator response, lung volumes, and methacholine challenge tests were reviewed for evidence of airway hyper-responsiveness (AHR). Comparisons were made between symptomatic versus asymptomatic individuals and FEV(1) values less than or greater than 100% of predicted. RESULTS A total of 280 studies were analyzed. During their clinical evaluation, 192 patients (69%) had post-bronchodilator spirometry recorded, 63 patients (23%) had lung volumes, and 36 patients (11%) completed methacholine challenge testing. Indications for spirometry included 193 symptomatic patients and 87 asymptomatic patients. Nearly 28% of patients with post-bronchodilator testing met criteria for AHR. No differences in AHR were found between the symptomatic and asymptomatic groups. The majority of patients (77%) with AHR had an FEV(1) < 100%, when compared to patients with an FEV(1) ≥ 100%. CONCLUSIONS A normal FEV(1) > 90% of predicted with obstructive indices may not represent a normal physiological variant, as 28% of patients were found to have underlying AHR. These findings suggest that clinicians should evaluate for AHR, especially in symptomatic patients, even if the FEV(1) is > 90% of predicted.
منابع مشابه
Bronchodilator responsiveness in patients with COPD.
The degree of acute improvement in spirometric indices after bronchodilator inhalation varies among chronic obstructive pulmonary disease (COPD) patients, and depends upon the type and dose of bronchodilator and the timing of administration. Acute bronchodilator responsiveness at baseline was examined in a large cohort of patients with moderate-to-very-severe COPD participating in the Understan...
متن کاملObstructive and restrictive spirometric patterns: fixed cut-offs for FEV1/FEV6 and FEV6.
The purpose of this study was to determine fixed cut-off points for forced expiratory volume in one second (FEV(1))/FEV(6) and FEV(6) as an alternative for FEV(1)/forced vital capacity (FVC) and FVC in the detection of obstructive and restrictive spirometric patterns, respectively. For the study, a total of 11,676 spirometric examinations, which took place on Caucasian subjects aged between 20-...
متن کاملDiagnosis of airway obstruction in the elderly: contribution of the SARA study
BACKGROUND The choice between lower limit of normal or fixed value of forced expiratory volume in one second/forced vital capacity ratio (FEV(1)/FVC) < 0.70 as the criterion for confirming airway obstruction is an open issue. In this study, we compared the criteria of lower limit of normal and fixed FEV(1)/FVC for diagnosis of airway obstruction, with a focus on healthy elderly people. METHOD...
متن کاملبررسی رابطه بین ائوزینوفیلی خلط با علائم و تستهای عملکرد ریوی در میان کارگران در مواجهه با گردوغبار آرد در نانواییها
Background: Occupational flour inhalation has been a culprit in commence of several pulmonary maladies, such as asthma. The flour particle is one of the most important factors which can cause occupational chronic respiratory disorders. We examined the relationship of occupational wheat flour inhalation in bakery and supermarket employees with pulmonary function, respiratory symptoms, and sputum...
متن کاملWhich spirometric indices best predict subsequent death from chronic obstructive pulmonary disease?
BACKGROUND Previous epidemiological studies have related mortality from chronic obstructive pulmonary disease (COPD) to forced expiratory volumes (FEV(1) or FEV(0.75)) and it is unknown whether other spirometric indices might have greater predictive power. METHODS A case-control study of fatal COPD was conducted within a cohort of London civil servants who performed forced expiratory spirogra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 57 4 شماره
صفحات -
تاریخ انتشار 2012