Surgical smoke and ultrafine particles

نویسندگان

  • Irene Brüske-Hohlfeld
  • Gerhard Preissler
  • Karl-Walter Jauch
  • Mike Pitz
  • Dennis Nowak
  • Annette Peters
  • H-Erich Wichmann
چکیده

BACKGROUND Electrocautery, laser tissue ablation, and ultrasonic scalpel tissue dissection all generate a 'surgical smoke' containing ultrafine (<100 nm) and accumulation mode particles (< 1 mum). Epidemiological and toxicological studies have shown that exposure to particulate air pollution is associated with adverse cardiovascular and respiratory health effects. METHODS To measure the amount of generated particulates in 'surgical smoke' during different surgical procedures and to quantify the particle number concentration for operation room personnel a condensation particle counter (CPC, model 3007, TSI Inc.) was applied. RESULTS Electro-cauterization and argon plasma tissue coagulation induced the production of very high number concentration (> 100000 cm-3) of particles in the diameter range of 10 nm to 1 mum. The peak concentration was confined to the immediate local surrounding of the production side. In the presence of a very efficient air conditioning system the increment and decrement of ultrafine particle occurrence was a matter of seconds, with accumulation of lower particle number concentrations in the operation room for only a few minutes. CONCLUSION Our investigation showed a short term very high exposure to ultrafine particles for surgeons and close assisting operating personnel - alternating with longer periods of low exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hiding in plain sight: Surgical smoke threatens health of OR staff.

1 Hiding in plain sight: Surgical smoke threatens health of OR staff Research has shown that electrosurgical smoke presents a serious health hazard for the OR team. However, many remain skeptical of its harmful effects, and compliance with smoke evacuation recommendations is not consistent. Electrosurgical smoke results from the vaporization of tissue, fluid, and blood into a gaseous form by el...

متن کامل

Ultrafine Particles from Traffic Emissions and Children’s Health (UPTECH) in Brisbane, Queensland (Australia): Study Design and Implementation

Ultrafine particles are particles that are less than 0.1 micrometres (µm) in diameter. Due to their very small size they can penetrate deep into the lungs, and potentially cause more damage than larger particles. The Ultrafine Particles from Traffic Emissions and Children's Health (UPTECH) study is the first Australian epidemiological study to assess the health effects of ultrafine particles on...

متن کامل

Ultrafine and respirable particles in an automotive grey iron foundry.

Ultrafine particle number and respirable particle mass concentrations were measured throughout an automotive grey iron foundry during winter, spring and summer using a particle concentration mapping procedure. Substantial temporal and spatial variability was observed in all seasons and attributed, in part, to the batch nature of operations, process emission variability and frequent work interru...

متن کامل

Nanoparticles in cigarette smoke; real-time undiluted measurements by a scanning mobility particle sizer

Cigarette smoke is a complex mixture of smoke constituents, often characterised by size-resolved particle distributions. Since descriptions of ultrafine particles <50 nm are absent, our aim was to explore the existence of these nanoparticles in fresh and undiluted cigarette smoke. We measured undiluted smoke particles real-time by a scanning mobility particle sizer with Faraday cup electrometer...

متن کامل

Exposure to fine and ultrafine particles from secondhand smoke in public places before and after the smoking ban, Italy 2005.

BACKGROUND A smoking ban in all indoor public places was enforced in Italy on 10 January 2005. METHODS We compared indoor air quality before and after the smoking ban by monitoring the indoor concentrations of fine (<2.5 microm diameter, PM2.5) and ultrafine particulate matter (<0.1 microm diameter, UFP). PM2.5 and ultrafine particles were measured in 40 public places (14 bars, six fast food ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Occupational Medicine and Toxicology (London, England)

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2008