Bioresorbable Vascular Scaffolds Versus Metallic Stents in Patients With Coronary Artery Disease: ABSORB China Trial.

نویسندگان

  • Runlin Gao
  • Yuejin Yang
  • Yaling Han
  • Yong Huo
  • Jiyan Chen
  • Bo Yu
  • Xi Su
  • Lang Li
  • Hai-Chien Kuo
  • Shih-Wa Ying
  • Wai-Fung Cheong
  • Yunlong Zhang
  • Xiaolu Su
  • Bo Xu
  • Jeffery J Popma
  • Gregg W Stone
چکیده

BACKGROUND The everolimus-eluting bioresorbable vascular scaffold (BVS) is designed to achieve results comparable to metallic drug-eluting stents at 1 year, with improved long-term outcomes. Whether the 1-year clinical and angiographic results of BVS are noninferior to current-generation drug-eluting stents has not been established. OBJECTIVES This study sought to evaluate the angiographic efficacy and clinical safety and effectiveness of BVS in a randomized trial designed to enable approval of the BVS in China. METHODS Eligible patients with 1 or 2 de novo native coronary artery lesions were randomized to BVS or cobalt-chromium everolimus-eluting stents (CoCr-EES) in a 1:1 ratio stratified by diabetes and the number of lesions treated. Angiographic and clinical follow-up were planned at 1 year in all patients. The primary endpoint was angiographic in-segment late loss (LL), powered for noninferiority with a margin of 0.15 mm. RESULTS A total of 480 patients were randomized (241 BVS vs. 239 CoCr-EES) at 24 sites. Acute clinical device success (98.0% vs. 99.6%; p = 0.22) and procedural success (97.0% and 98.3%; p = 0.37) were comparable in BVS- and CoCr-EES-treated patients, respectively. The primary endpoint of in-segment LL at 1 year was 0.19 ± 0.38 mm for BVS versus 0.13 ± 0.38 mm for CoCr-EES; the 1-sided 97.5% upper confidence limit of the difference was 0.14 mm, achieving noninferiority of BVS compared with CoCr-EES (pnoninferiority = 0.01). BVS and CoCr-EES also had similar 1-year rates of target lesion failure (cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization; 3.4% vs. 4.2%, respectively; p = 0.62) and definite/probable scaffold/stent thrombosis (0.4% vs. 0.0%, respectively; p = 1.00). CONCLUSIONS In the present multicenter randomized trial, BVS was noninferior to CoCr-EES for the primary endpoint of in-segment LL at 1 year. (A Clinical Evaluation of Absorb Bioresorbable Vascular Scaffold [Absorb BVS] System in Chinese Population-ABSORB CHINA Randomized Controlled Trial [RCT]; NCT01923740).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.

OBJECTIVES The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. BACKGROUND The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the X...

متن کامل

Long-Term Efficacy and Safety of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents

Second-generation metallic drug-eluting stents (DES) have been widely recommended for percutaneous coronary intervention. One of the main drawbacks of these devices is the risk of late adverse events (ie, beyond 1 year), particularly repeat revascularization, which are partly related to the persistence of the metallic stents in the coronary artery wall. In this context, the bioresorbable vascul...

متن کامل

Tension gastrothorax mimicking acute coronary syndrome and causing cardiac arrest.

Veldhof S, Rapoza R, Onuma Y, Garcia-Garcia HM, Chevalier B. ABSORB II randomized controlled trial: a clinical evaluation to compare the safety, efficacy, and performance of the Absorb everolimus-eluting bioresorbable vascular scaffold system against the XIENCE everolimus-eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary art...

متن کامل

Bioresorbable polymeric scaffolds for coronary revascularization: Lessons learnt from ABSORB III, ABSORB China, and ABSORB Japan

Bioresorbable polymers and biocorrodible metals are the latest developments in biodegradable materials used in interventional cardiology for the mechanical treatment of coronary atherosclerosis. Poly-L-lactic acid is the most frequently used bioresorbable polymer and initial evidence of feasibility, efficacy and clinical safety following deployment of polymer-based platforms was gained after co...

متن کامل

The first generation ABSORB BVS scaffold; to be or not to be?

In the routine treatment of coronary artery disease, balloon angioplasty has been replaced by stents. The use of bare-metal stents resulted in lower rates of restenosis and repeat revascularisations. Drug-eluting stents (DES), designed with thinner struts and anti-proliferative drugs, have further enhanced the efficacy and safety of percutaneous coronary intervention. Nevertheless, the new gene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 66 21  شماره 

صفحات  -

تاریخ انتشار 2015