Bronchodilator delivery during simulated pediatric noninvasive ventilation.
نویسندگان
چکیده
BACKGROUND Noninvasive ventilation (NIV) is usually applied using bi-level positive airway pressure devices, and many of these devices use a single-limb patient circuit with an integrated leak port to purge the circuit of exhaled carbon dioxide. Sometimes bronchodilator therapy is indicated in pediatric patients, but there have been no studies of the optimal nebulizer position, with respect to leak, during pediatric NIV. We hypothesized that there would be no differences in albuterol delivery with a vibrating-mesh nebulizer between 3 different positions/exhalation leak valve combinations in the patient circuit during simulated pediatric NIV. METHODS A simulated upper airway model was attached to a lung model that simulated spontaneous breathing. A noninvasive ventilator equipped with heated wire circuit and heated humidifier was attached to the lung model via a pediatric oronasal mask. Albuterol (5 mg) was delivered with a vibrating-mesh nebulizer, at 3 different circuit position/leak condition combinations: prior to the humidifier and leak valve; between the humidifier and leak valve; and integrated within the mask and after the leak. Albuterol was captured on a filter and quantified with chromatography. RESULTS Greater albuterol mass was delivered to the filter with the nebulizer integrated into the mask than at any other testing condition (P < .001). In the conditions where the nebulizer was placed prior to the exhalation leak valve, greater drug delivery was observed when the nebulizer was placed proximal to the mask (position 2) than when placed prior to the humidifier (position 3, P = .002). CONCLUSIONS Albuterol delivery during simulated pediatric NIV was affected by the position of the nebulizer in relation to the expiratory leak valve and the nebulizer's distance from the filter. A vibrating-mesh nebulizer placed intra-mask may provide a better alternative for medication delivery than those previously used during pediatric NIV.
منابع مشابه
Clinical Controversies in Aerosol Therapy for Infants and Children.
Pediatric patients are different from adult patients with respect to airway anatomy and breathing patterns. They are also incapable of following commands and often reject breathing treatments. For these reasons, aerosol drug delivery is one of the most technically challenging aspects for clinicians providing respiratory care to young children. Improvements in nebulizer technology have provided ...
متن کاملAerosol Therapy During Noninvasive Ventilation or High-Flow Nasal Cannula.
Noninvasive ventilation (NIV) and high-flow nasal cannula (HFNC) are increasingly used for patients with acute respiratory failure. Some patients receiving these therapies might also benefit from inhaled drug delivery. Thus, it is attractive to combine aerosol therapy with NIV or HFNC. The purpose of this paper is to review the available evidence related to the use of inhaled aerosols with NIV ...
متن کاملClearing the mist from our eyes: bronchodilators, mechanical ventilation, new devices, locations, and what you should know about bias flow.
Patients with obstructive lung disease often present with life-threatening respiratory failure, confounded by severe air-flow limitation, dynamic hyperinflation, intrinsic PEEP, reduced pulmonary compliance, hypercarbia, and hemodynamic instability. Inhaled bronchodilators play a vital role in the care of such patients and are one of the most widely prescribed medications in the critical care s...
متن کاملAerosol bronchodilator therapy during noninvasive positive-pressure ventilation: a peek through the looking glass.
Exacerbations of chronic obstructive pulmonary disease (COPD) are a common cause of acute respiratory failure,1 leading to over 700,000 hospitalizations annually in the United States.2 Approximately 50% of patients suffering hypercapnic respiratory failure from exacerbations of COPD require some form of ventilatory support.3 The ventilatory strategy employed in such patients has evolved during ...
متن کاملFactors affecting bronchodilator delivery in mechanically ventilated adults.
BACKGROUND Bronchodilators are increasingly being used in patients undergoing mechanical ventilation. There are multiple factors that affect bronchodilator delivery during mechanical ventilation. These factors can be classified into three categories: ventilator-related factors, circuit-related factors and device-related factors. AIMS The purpose of this paper is to review in depth each of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 58 9 شماره
صفحات -
تاریخ انتشار 2013