Origin of the third heart sound.
نویسندگان
چکیده
We report noninvasive and invasive studies designed to clarify the mechanism of the third heart sound (S3) in humans. The noninvasive observations were made using a miniature accelerometer attached to the skin surface at the cardiac apex. In subjects with no S3, the tracings were either flat or showed very low undulations throughout diastole. Those with an S3, however, demonstrated a distinct reduction of acceleration, or negative jerk, of the rapid filling movement at the apex at the time of the sound. The invasive studies in the cardiac catheterization laboratory consisted offrame-by-frame measurements of left ventricular dimensions in the transverse and long axes during early diastole in patients with diastolic overload abnormalities to investigate the temporal sequence of filling in these two principal axes. The maximal long-axis filling rate occurred after the short axis, a finding that helps to resolve a discrepancy noted in the time of maximal short-axis filling and S3 production. These studies support the concept that the S3 is due to a sudden intrinsic limitation of longitudinal expansion of the left ventricular wall during early diastolic filling, resulting in a negative jerk that is transmitted to the skin surface.
منابع مشابه
Analysis of different angles passive verb in the Quran (Sura Baqara case study)
Passive verb in Arabic language is a process of sound and sound Mnzrgahhay, derivative, semantic, and syntactic, as well as various other aspects of the research we undertake is not under investigation . Due to the structure of active and passive aspects, has long been under consideration during the study of language and linguistics at angles without the element somehow found the Byshtrdst . In...
متن کاملA New Method to Improve Automated Classification of Heart Sound Signals: Filter Bank Learning in Convolutional Neural Networks
Introduction: Recent studies have acknowledged the potential of convolutional neural networks (CNNs) in distinguishing healthy and morbid samples by using heart sound analyses. Unfortunately the performance of CNNs is highly dependent on the filtering procedure which is applied to signal in their convolutional layer. The present study aimed to address this problem by a...
متن کاملHeart Sounds in Patients with Homograft
Phonocardiographic, hemodynamic, angiographic, and cardiac echographic studies have been performed on 11 patients whose diseased mitral valves have been replaced by a supported aortic valve homograft. The chordae tendineae and papillary muscles were removed in all patients during the operation. Apical first heart sounds of normal intensity were present in all patients after surgery. Nine patien...
متن کاملHeart sounds in patients with homograft replacement of the mitral valve.
Phonocardiographic, hemodynamic, angiographic, and cardiac echographic studies have been performed on 11 patients whose diseased mitral valves have been replaced by a supported aortic valve homograft. The chordae tendineae and papillary muscles were removed in all patients during the operation. Apical first heart sounds of normal intensity were present in all patients after surgery. Nine patien...
متن کاملHeart Sounds in Patients with Homograft Replacement of the Mitral Valve By RALPH
Phonocardiographic, hemodynamic, angiographic, and cardiac echographic studies have been performed on 11 patients whose diseased mitral valves have been replaced by a supported aortic valve homograft. The chordae tendineae and papillary muscles were removed in all patients during the operation. Apical first heart sounds of normal intensity were present in all patients after surgery. Nine patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British medical journal
دوره 3 5664 شماره
صفحات -
تاریخ انتشار 1969