Disinfection of upper gastrointestinal fibreoptic endoscopy equipment: an evaluation of a cetrimide chlorhexidine solution and glutaraldehyde.
نویسندگان
چکیده
There is little information available on the bacteriological contamination of upper gastrointestinal fibreoptic endoscopes during routine use and the effects of 'disinfecting solutions'. A bacteriological evaluation was therefore made of cleaning an endoscope and its ancillary equipment with (1) water, (2) an aqueous solution of 1% cetrimide with 0.1% chlorhexidine, and (3) activated aqueous 2% glutaraldehyde. All equipment, but particularly the endoscope itself, was found to be heavily contaminated after use with a wide variety of organisms of which 53% were Gram positive. Cleaning the endoscope and ancillary equipment with water and the cetrimide/chlorhexidine solution alone or in combination was inadequate to produce disinfection but immersion in glutaraldehyde for two minutes consistently produced sterile cultures with our sampling technique. A rapid and simple method for disinfection of endoscopic equipment is therefore recommended and we think this is especially suitable for busy endoscopy units.
منابع مشابه
Risk of Hepatitis C Virus transmission Following Upper Gastrointestinal Endoscopy
Background: Hepatitis C virus infection (HCV) is a main health problem in our country. It is thought that the transmission of hepatitis C virus (HCV) through the endoscopic procedures is a rare event. The aim of this study was to evaluate the risk of conventional disinfection in the transmission of HCV. Materials and methods: A prospective study, comprising 456 consecutive upper gastrointestin...
متن کاملElimination of high titre HIV from fibreoptic endoscopes
Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the k...
متن کاملElimination of high titre HIV from fibreoptic endoscopes.
Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the k...
متن کاملNew disinfecting apparatus for gastrointestinal fibre-endoscopes.
Bacterial contamination of gastrointestinal fibre-endoscopes is a potential source of clinically significant infection. Aqueous 2% alkaline glutaraldehyde adequately disinfects fibre-endoscopes but may cause serious sensitivity reactions among endoscopy staff. A new 'closed-system' disinfecting apparatus is described that disinfects with glutaraldehyde for 30 minutes before an endoscopy session...
متن کاملCleaning and disinfection of equipment for gastrointestinal flexible endoscopy: interim recommendations of a Working Party of the British Society of Gastroenterology.
1. All patients undergoing gastrointestinal endoscopy must be considered 'at risk' for HIV and appropriate cleaning/disinfection measures taken for endoscopes and accessories. 2. Thorough manual cleaning with detergent, of the instrument and its channels is the most important part of the cleaning/disinfection procedure. Without this, blood, mucus and organic material will prevent adequate penet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gut
دوره 19 10 شماره
صفحات -
تاریخ انتشار 1978