Matrix Solid-Phase Dispersion Extraction and Quantification of Alpinetin in Amomum Seed using Validated HPLC and HPTLC Methods
نویسندگان
چکیده
Alpinetin is a flavonoidal constituent of seeds of Amomum subulatum Roxb., recently reported to possess vasorelaxant and antiHIV activities. Simple, accurate and precise HPLC and HPTLC methods were developed for the analysis of alpinetin in A. subulatum seed extracts and extraction technique was optimized to get maximum yield using conventional, ultrasonic and matrix solid phase dispersion extraction. HPLC was performed on a C18 column with methanol and water (70:30, v/v) as mobile phase at a flow rate of 1.0 ml/min whereas HPTLC on silica aluminum sheet (60F254) using toluene, dichloromethane and ethyl acetate as solvent system. A sharp peak was obtained for alpinetin at a retention time (Rt) of 5.7 min by HPLC and retardation factor (Rf) of 0.48 by HPTLC. Both methods were validated as per the ICH guidelines and the content of alpinetin was estimated in different extracts. Matrix solid phase dispersion technique was found most suitable for extracting alpinetin as compared to other techniques. Validation data are indicative of good precision and accuracy and proved the reliability of the methods.
منابع مشابه
Determination of Malathion and α-Endosulfan Residue in Khazar Rice Using Matrix Solid Phase Dispersion and HPLC
An extraction method based on matrix solid phase dispersion (MSPD) and high performance liquid chromatography with UV detection for quantification of two widely used pesticides (Malathion and α-Endosulfan) in Khazar rice from north of Iran were investigated. The ratio of solid phase (adsorbent) to sample, types of eluting solvent and its volume were optimized to achieve the highest recoveries f...
متن کاملAn improved HPLC method for determination of colocynthin in colocynth
Background and objectives: Colocynthin is the major active secondary metabolite of colocynth, Citrullus colocynthis (L.) Schrad, which has been used in traditional and ethno medicine of many countries. It could be considered as an active marker for quality control of colocynth and its herbal products. Analysis and standardization of colocynth and its herbal preparations are a critical...
متن کاملQuantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods
Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...
متن کاملQuantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods
Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...
متن کاملSelective Extraction and Determination of Di(2-ethylhexyl) Phthalate in Aqueous Solution by HPLC Coupled with Molecularly Imprinted Solid-phase Extraction
Surface Molecularly Imprinted Polymer (SMIP) for selective adsorption of di(2-ethylhexyl) phthalate(DEHP) was prepared on the surface of silica gel which was modified by aminopropyltriethoxysilane and acryloyl chloride in a two-step method. The prepared SMIP was used to prepare Molecularly Imprinted Solid-Phase Extraction (MISPE) column for selective extraction of DEHP from aqueous solution...
متن کامل