Embol-X intra-aortic filtration system: capturing particulate emboli in the cardiac surgery patient.
نویسندگان
چکیده
We sought to evaluate the effectiveness of using an intra-aortic filtration system for the prevention of particulate emboli transport and the minimization of significant postoperative complications associated with particulate emboli. Between October of 2000 and October 2001, a total of 146 patients were enrolled at Advocate Christ Medical Center as part of the multi-institutional randomized trial (1289 patients at 22 centers). A total of 74 patients (51%) received the Embol-X intra-aortic filter and 72 patients (49%) were enrolled in the control group. Patients were evaluated for neurological deficit, myocardial infarction, renal insufficiency/failure, limb ischemia, and death at 12-hour, 24-hour, 72-hour, 7-day, and 30-day postoperative intervals. All filters received histological examination for particulate matter. Particulate matter was isolated in 70 (94.5%) of the filters successfully deployed. There was no statistically significant difference in the device related events between the filter and conventional cannulation groups (9/74 = 12.1% vs. 7/72 = 9.7%). Although not clinically evident, the primary event for both groups was ascending aortic intimal tears. There was one death in each of the groups not related to the filter or cannula used. The use of the Embol-X intra-aortic filter system has proven to be a safe and effective means to reduce the introduction of particulate emboli into the systemic circulation. Clearly, the reduction of particulate matter by as much as 95% justifies its use in cardiac surgery patients identified with an increased pre-operative embolic risk.
منابع مشابه
Particulate emboli capture by an intra-aortic filter device during aortic valve replacement.
OBJECTIVE This study aims to analyze the embolic activity in patients with calcified aortic stenosis who underwent aortic valve replacement using intra-aortic filtration with an EMBOL-X System device (Edwards Lifesciences Inc., Mountain View, CA, USA). METHODS From January 2007 to July 2007, 13 consecutive patients with calcified aortic stenosis, who underwent isolated aortic valve replacemen...
متن کاملReduction of neurologic complications by intra-aortic filtration in patients undergoing combined intracardiac and CABG procedures.
OBJECTIVE Patients undergoing combined intracardiac and coronary artery bypass grafting (CABG) procedures are at high risk for neurologic events. Previously the Multicenter Study of Perioperative Ischemia (McSPI) Study Group demonstrated that risk factors for neurologic complications in these patients related primarily to embolization. OBJECTIVE This study investigated risk factors and outcom...
متن کاملStay off-pump and do not touch the aorta!
One of the major drawbacks in contemporary on-pump coronary artery bypass surgery is the inherent risk of intraoperative stroke. In addition, neurophysiological dysfunction and neurobehavioural changes have been reported in variable frequencies following on-pump bypass surgery. Cardiopulmonary bypass (CPB) causes a systemic inflammatory response, haemodilution, change in vascular resistance, ab...
متن کاملThe incidence of emboli during cardiac surgery: a histopathologic analysis of 2297 patients.
OBJECTIVE Manipulation of the atherosclerotic aorta during cardiac surgery is assumed to cause embolization, which can contribute to adverse outcomes. Recently, as a result of worldwide trials deploying the Embol-X intraaortic filter during cardiac surgery, such emboli were captured and processed for histopathologic analysis. METHODS Filters with a pore size of 120 microns were placed in 2297...
متن کاملThe Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 37 2 شماره
صفحات -
تاریخ انتشار 2005