Stress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT.

نویسندگان

  • Kheng-Thye Ho
  • Kia-Chong Chua
  • Ernst Klotz
  • Christoph Panknin
چکیده

OBJECTIVES This study sought to describe a protocol for myocardial perfusion imaging using dipyridamole stress, with 128-slice dual-source computed tomography (CT), and to assess the ability of CT myocardial perfusion imaging (MPI) to detect abnormal flow reserve and infarction in comparison with nuclear MPI (NMPI). BACKGROUND CT MPI has not been previously described with the 128-slice dual-source CT scanner, or with the complete evaluation of dynamic time-attenuation curves of the myocardium. METHODS Thirty-five patients underwent a stress CT MPI protocol. Complete time-attenuation curves of the myocardium were acquired using a novel scan mode, which acquires prospectively electrocardiogram (ECG)-triggered axial images at 2 rapidly alternating positions. Myocardial blood flow (MBF) values of fixed and reversible defects obtained were compared between rest and stress. Findings on CT MPI were correlated to NMPI. Perfusion defects detected on CT were correlated to coronary stenoses detected on CT angiography (CTA) and invasive coronary angiography (ICA). RESULTS There was a 1.5-fold difference between stress (1.21 +/- 0.31 cc/cc/min) and rest (0.82 +/- 0.22 cc/cc/min) MBF in normal tissue. In reversible defects, MBF was 0.65 +/- 0.21 cc/cc/min and 0.63 +/- 0.18 cc/cc/min at stress and rest, respectively. In fixed defects, the MBF was 0.57 +/- 0.22 cc/cc/min at stress and 0.54 +/- 0.23 cc/cc/min at rest. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT MPI for identifying segments with perfusion defects was 0.83, 0.78, 0.79, and 0.82, respectively. ICA results were available for 30 patients. Sensitivity, specificity, PPV, and NPV of CT MPI compared with ICA were 0.95, 0.65, 0.78, and 0.79, respectively. The radiation dose for CT MPI was 9.15 +/- 1.32 mSv for the stress scan and 9.09 +/- 1.40 mSv for the rest scan. CONCLUSIONS Vasodilator-stress CT MPI may be feasible in human subjects at a radiation dose similar to NMPI. It identifies areas of abnormal flow reserve and infarction with a high degree of correlation to NMPI as well as to stenoses detected in CTA and ICA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging

Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...

متن کامل

Multimodality cardiac imaging in Clozapine-induced eosinophilic constrictive perimyocarditis.

tion of hemodynamically significant coronary artery stenosis: incremental diagnostic value of dynamic CT-based myocardial perfusion imaging. of dynamic computed tomography adenosine stress myocardial perfusion imaging in estimating myocardial blood flow at various degrees of coronary artery stenosis using a porcine animal model. A et al. Computed tomography stress myocardial perfusion imaging i...

متن کامل

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

Coronary artery calcium (CAC) score – a prognostic tool in coronary artery disease?

Introduction: The aim of this study was to evaluate the impact of measurement of coronary artery calcification score (CAC) in patients with suspected coronary artery disease (CAD) and a normal myocardial perfusion scan. Methods: In a prospective study we measured the calcium score of 74 patients (29 m, 45 f, mean age 58.7 (m) and 64.4 (f)) with suspicion of CAD and a normal perfusion scan. In ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 3 8  شماره 

صفحات  -

تاریخ انتشار 2010