Intraarterial chemotherapy for brain tumors by using a spatial dose fractionation algorithm and pulsatile delivery.
نویسندگان
چکیده
PURPOSE To evaluate the cause of complications in intraarterial chemotherapy for brain tumors and validate a dosage algorithm based on arterial territory. MATERIALS AND METHODS Four hundred sixty-two procedures were performed in 113 patients. Technique included pulsatile infusion of a chemotherapeutic agent. Dosage was calculated per hemisphere and divided per arterial territory according to a spatial dose fractionation algorithm based on the vascular territories of major cerebral arteries: middle cerebral artery, 60%; anterior cerebral artery, 20%; posterior cerebral artery, 15%; and perforator arteries, 5%. Hospital charts of all patients were retrospectively reviewed for complications, with specific attention given to the angiograms to determine a cause. Then, subgroup analysis of the chemotherapy protocol with the largest patient population was performed to evaluate predictors of complications. RESULTS Six (1.3%) complications were asymptomatic; 12 (2.6%), transient neurologic; three (0.6%), permanent minor neurologic; three (0.6%), permanent major neurologic; and 32 (7.0%), seizures. In the subgroup analysis, the hemispheric dose administered according to the algorithm was strongly predictive of seizure and neurologic deficit. CONCLUSION Neurotoxicity of intraarterial cerebral chemotherapy can be minimized by using pulsatile injection and the described spatial dose fractionation algorithm.
منابع مشابه
Verification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors
Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general, the uncertainty in the dose delivered should fall within ± 5% of the...
متن کاملAchievable accuracy in brain tumors by in vivo dosimetry with diode detectors
ABSTRACT Background: In vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. Uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by ICRU. Assessment of dose for radiotherapy applications performed with various types of detectors. In this study, semiconductor diodes were used which have s...
متن کاملSpatial memory and changes in expression of genes of neurotrophic factors in adult rat brain after fractionated whole brain irradiation
Background: Ionizing radiation causes cognitive impairment in adult brain. However, the effects of various irradiation protocols with fractionated fixed total dose on hippocampal function have not yet been studied. Materials and Methods: Fractionated whole brain irradiation with a total dose of 36 Gy was performed according to the following protocols: 2Gy-18 fractions (2Gy*18), 4Gy-9 fraction (...
متن کاملComputerized Addenbrooke’s Cognitive Examination for Neurocognitive Monitoring of Children with Benign and Malignant Brain Cerebellar Tumor
Background: Brain tumors in the cerebellum site, especially in the cranial nuclei, are most commonly associated with cognitive impairment in children, but the differences in dimensions of cognitive impairments in pediatric benign and malignant tumors are rarely studied. Meanwhile, cognitive impairments in this area are required to be widely studied. This study aimed at using Computerized Addenb...
متن کاملMagnetic Graphene Oxide Nanocarrier as a drug delivery vehicle for MRI monitored magnetic targeting of rat brain tumors
Introduction: Glioblastoma multiform is the most common malignant brain tumor, with an invasive nature. Despite the development of conventional therapies such as surgery, radiotherapy and chemotherapy, because of high recurrence rates, the prognosis remains very poor. Over the last decade, nanotechnology has represented an innovative method as nanoparticle-based drug delivery ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 218 3 شماره
صفحات -
تاریخ انتشار 2001