[The geometry of the keel determines the behaviour of the tibial tray against torsional forces in total knee replacement].
نویسندگان
چکیده
The keel design of the tibial tray is essential for the transmission of the majority of the forces to the peripheral bone structures, which have better mechanical proprieties, thus reducing the risk of loosening. The aim of the present study was to compare the behaviour of different tibial tray designs submitted to torsional forces. Four different tibial components were modelled. The 3-D reconstruction was made using the Mimics software. The solid elements were generated by SolidWorks. The finite elements study was done by Unigraphics. A torsional force of 6 Nm. applied to the lateral aspects of each tibial tray was simulated. The GENUTECH® tibial tray, with peripheral trabecular bone support, showed a lower displacement and less transmitted tensions under torsional forces. The results suggest that a tibial tray with more peripheral support behaves mechanically better than the other studied designs.
منابع مشابه
Total Knee Replacement Sizing: Shoe Size Is a Better Predictor for Implant Size than Body Height
Background: Various sizes of implants need to be available during surgery. The purpose of this paper is to comparebody height and shoe size with implant sizes in patients who underwent total knee replacement surgery to see whichbiomarker is a better predictor for preoperative planning to determine implant size.Methods: A total of 100 knees, belonging to 50 females and 50 males, were observed. P...
متن کامل•The Effect of Peg vs. Keel Fixation on Micromotion of Cementless Tibial Baseplates
INTRODUCTION: Initial implant stability is crucial to cementless knee replacement success, however the optimal design remains elusive. Previous biomechanical studies have aimed at quantifying initial stability using simplified loading scenarios. The objective of this study was to use a physiological relevant methodology which incorporates torsion, shear and compression forces to evaluate tibial...
متن کاملTibial forces measured in vivo after total knee arthroplasty.
An instrumented tibial prosthesis was developed to measure forces in vivo after total tibial arthroplasty. This prosthesis was implanted in a 67-kg, 80-year-old man. The prosthesis measured forces at the 4 quadrants of the tibial tray. Tibial forces were measured postoperatively during rehabilitation, rising from a chair, standing, walking, and climbing stairs. By the sixth postoperative week, ...
متن کاملComparison of tibial bone coverage of 6 knee prostheses: a magnetic resonance imaging study with controlled rotation.
PURPOSE To compare the extent of tibial bone covered by the tibial tray in 6 most commonly used total knee arthroplasty designs in order to strike a balance between mediolateral cortical fit and optimal tibial component rotation. METHODS In 74 men and 27 women aged 17 to 60 (mean, 32) years with suspected soft-tissue injuries, their magnetic resonance images of the knee in full extension were...
متن کاملبررسی عوامل احتمالی مؤثر بر نتیجه نهایی عمل استئوتومی پروگزیمال تیبیادر استئوآرتریت کمپارتمان داخلی زانو
Introduction: Excellent results are obtained with high tibial osteotomy in patients suffering from the osteoarthritis of the medial compartment of the knee however, poor results have been reported in 10 to 50 percent of the cases. The aim of this study was to evaluate the probable factors influencing the outcome of high tibial osteotomy to let us select the proper cases for this surgery. Pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de cirugia ortopedica y traumatologia
دوره 58 6 شماره
صفحات -
تاریخ انتشار 2014