Comparison of the performance of four laryngoscopes in a high-fidelity simulator using normal and difficult airway.

نویسندگان

  • L Powell
  • J Andrzejowski
  • R Taylor
  • D Turnbull
چکیده

BACKGROUND Novel laryngoscopes may demonstrate advantages over the traditional Macintosh laryngoscope for difficult airways. Our study compared Glidescope laryngoscope, Bonfils fibrescope, and CTrach intubating laryngeal mask airway with the Macintosh laryngoscope in a simulated normal and difficult airway, considering the additional effect of previous intubation experience. METHODS Twenty-two non-anaesthetists, 21 trainees, and 20 consultant anaesthetists attempted tracheal intubation of a Laerdal SimMan manikin, comparing a normal with a difficult airway scenario for each intubation device. The time taken to view the vocal cords and time to intubate were recorded. Also success rate and ease of use for each device were scored, alongside scope preference for each scenario. RESULTS Time to intubate was significantly shorter with the Macintosh compared with all three novel devices. All the devices had a high first-attempt success rate, but the Glidescope had a 100% first time successful intubation for all participants in both a normal and a difficult airway. Non-anaesthetists took significantly longer time to intubate compared with consultant anaesthetists, but there was no difference between trainee and consultant anaesthetists. Higher proportions of participants found the Glidescope easy to use, compared with other devices. For the normal airway, the Macintosh was the preferred device, but for the difficult airway, the Glidescope was favoured. CONCLUSIONS In this study, the Macintosh laryngoscope outperformed the other devices. However, the Glidescope was considered easy to use regardless of previous experience and was the preferred device for the simulated difficult airway.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective randomized high fidelity simulation center based side-by-side comparison analyzing the success and ease of conventional versus new generation video laryngoscope technology by inexperienced laryngoscopists

Introduction. Indirect video laryngoscopes are altering the landscape of airway management. The primary aim of this prospective randomized patient simulator analysis was to objectively compare video laryngoscopes to standard airway management techniques in novice users. Methods. "First year medical students were exposed to high-fidelity simulated normal and difficult airway scenarios while usin...

متن کامل

A comparison of the force applied on oral structures during intubation attempts between the Pentax-AWS airwayscope and the Macintosh laryngoscope: a high-fidelity simulator-based study

OBJECTIVE We sought to determine whether the use of Pentax-AWS Airwayscope (AWS) applied less force on oral structures during intubation attempts than a conventional direct laryngoscope (DL). DESIGN Prospective cross-over study. PARTICIPANTS A total of 37 physicians (9 transitional-year residents, 20 emergency medicine residents and 8 emergency physicians) were enrolled. INTERVENTIONS We ...

متن کامل

Comparison of the force applied on oral structures during intubation attempts by novice physicians between the Macintosh direct laryngoscope, Airway Scope and C-MAC PM: a high-fidelity simulator-based study

OBJECTIVE We examined whether the use of Airway Scope (AWS) and C-MAC PM (C-MAC) decreased the force applied on oral structures during intubation attempts as compared with the force applied with the use of Macintosh direct laryngoscope (DL). DESIGN Prospective cross-over study. PARTICIPANTS A total of 35 novice physicians participated. INTERVENTIONS We used 6 simulation scenarios based on...

متن کامل

Comparison Upper Lip Bite Test and Mallampati Test in the Prediction of Difficult Laryngoscopy

Background and Objective: Intubation is the most common method for the management of the upper airway in general anesthesia. In this regard, the prediction of the ease or difficulty of intubation is of paramount importance for the anesthesia team. The main cause of anesthesia-related mortality is failed airway management. The present study aimed to compare the accuracy of the upper lip bite (UL...

متن کامل

Assessment of the storz video Macintosh laryngoscope for use in difficult airways: A human simulator study.

OBJECTIVES Video laryngoscopy has been shown to improve glottic exposure when compared to direct laryngoscopy in operating room studies. However, its utility in the hands of emergency physicians (EPs) remains undefined. A simulated difficult airway was used to determine if intubation by EPs using a video Macintosh system resulted in an improved glottic view, was easier, was faster, or was more ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 103 5  شماره 

صفحات  -

تاریخ انتشار 2009