Monitoring pediatric dental patients with nasal mask capnography.

نویسندگان

  • R E Primosch
  • I M Buzzi
  • G Jerrell
چکیده

PURPOSE The purpose of this study was to evaluate the potential of using capnography to analyze respiratory samples taken from a scavenging nitrous oxide nasal hood during routine pediatric dental procedures. METHODS Twenty-two subjects, aged 60-116 months, were administered alternately either 40% nitrous oxide/60% oxygen or 100% oxygen during two sequential restorative appointments. All subjects were monitored continuously for end-tidal carbon dioxide and respiratory rate using a capnograph whose sampling line was attached directly to the nitrous oxide nasal hood. The subject's breath sound, displayed behavior, type of dental procedure being performed, and presence of rubber dam isolation were recorded every minute throughout the two appointments. RESULTS Values for end-tidal carbon dioxide and respiratory rate were displayed on the capnograph when administering either oxygen or a combination of nitrous oxide/oxygen inhalation through the nasal hood. These respiratory values were lowered significantly when comparing 40% nitrous oxygen-60% oxygen to 100% oxygen inhalation. They were not significantly altered by the type of breath sound, patient behavior, dental procedure, or presence of rubber dam isolation, with the exception of some dental procedures which significantly lowered end-tidal carbon dioxide. The apnea alarm on the capnograph occurred during 5% of the total treatment time, but its occurrence represented a 97% false positive rate. The occurrence of the apnea alarm was significantly associated with the type for breath sound, patient behavior, and dental procedure. When used in this manner, the capnograph was effective in alerting the practitioner to potential apneic events, but likely has limited value in monitoring valid end-tidal carbon dioxide levels due to limitations in the sampling technique. CONCLUSIONS This study demonstrated the potential of the capnograph as a respiratory monitor for pediatric dental patients when the sampling line was attached to a scavenging nitrous oxide nasal hood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation of capnography and pulse oximetry as monitors of pediatric patients sedated for dental treatment.

Traditional methods of monitoring sedated pediatric dental patients have major shortcomings. This study evaluated the use of capnography in conjunction with pulse oximetry for monitoring children during conscious sedation for dental treatment. The specific purposes of the study were to determine if capnography would: (1) detect ventilatory changes that subsequently cause an oxyhemoglobin desatu...

متن کامل

Accuracy of acoustic respiration rate monitoring in pediatric patients.

BACKGROUND Rainbow acoustic monitoring (RRa) utilizes acoustic technology to continuously and noninvasively determine respiratory rate from an adhesive sensor located on the neck. OBJECTIVE We sought to validate the accuracy of RRa, by comparing it to capnography, impedance pneumography, and to a reference method of counting breaths in postsurgical children. METHODS Continuous respiration r...

متن کامل

A comparison of conventional versus electronic monitoring of sedated pediatric dental patients.

The first purpose of this study was to compare traditional monitoring methods to electronic instruments for monitoring physiologic parameters during conscious sedation of pediatric dental patients. Traditional methods included careful visual assessment of skin color, airway patency and chest movements, and auscultation of breath and heart sounds using a precordial stethoscope; electronic instru...

متن کامل

Description of an assembled noninvasive capnography setup.

BACKGROUND Noninvasive capnography is not routinely available on portable transport patient monitors but can be useful in respiratory monitoring of spontaneously breathing patients during transport, especially when sedation is administered. We describe an assembled setup of face mask capnography. The purpose of this study was to assess the feasibility and performance of an assembled face mask c...

متن کامل

Respiratory monitoring during pediatric sedation: pulse oximetry and capnography.

A major concern in pediatric dentistry is maximizing risk management through optimal monitoring of respiratory function during sedation techniques. This article examines the problems inherent in respiratory monitoring in sedated pediatric dental patients, the traditional methods of respiratory monitoring, and new technologies which are useful in optimizing respira tory monitoring. The authors d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatric dentistry

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2000