National Population-Based Study Comparing Treatment-Related Toxicity in Men Who Received Intensity Modulated Versus 3-Dimensional Conformal Radical Radiation Therapy for Prostate Cancer.
نویسندگان
چکیده
PURPOSE To compare, in a national population-based study, severe genitourinary (GU) and gastrointestinal (GI) toxicity in patients with prostate cancer who were treated with radical intensity modulated radiation therapy (IMRT) or 3-dimensional conformal radiation therapy (3D-CRT). METHODS AND MATERIALS Patients treated with IMRT (n=6933) or 3D-CRT (n=16,289) between January 1, 2010 and December 31, 2013 in the English National Health Service were identified using cancer registry data, the National Radiotherapy Dataset, and Hospital Episodes Statistics, the administrative database of care episodes in National Health Service hospitals. We developed a coding system that identifies severe toxicity (at least grade 3 according to the National Cancer Institute Common Terminology Criteria for Adverse Events scoring system) according to the presence of a procedure and a corresponding diagnostic code in patients' Hospital Episodes Statistics records after radiation therapy. A competing risks regression analysis was used to estimate hazard ratios (HRs), comparing the incidence of severe GI and GU complications after IMRT and 3D-CRT, adjusting for patient, disease, and treatment characteristics. RESULTS The use of IMRT, as opposed to 3D-CRT, increased from 3.1% in 2010 to 64.7% in 2013. Patients who received IMRT were less likely than those receiving 3D-CRT to experience severe GI toxicity (4.9 vs 6.5 per 100 person-years; adjusted HR 0.66; 95% confidence interval 0.61-0.72) but had similar levels of GU toxicity (2.3 vs 2.4 per 100 person-years; adjusted HR 0.94; 95% confidence interval 0.84-1.06). CONCLUSIONS Prostate cancer patients who received radical radiation therapy using IMRT were less likely to experience severe GI toxicity, and they had similar GU toxicity compared with those who received 3D-CRT. These findings in an unselected "real-world" population support the use of IMRT, but further cost-effectiveness studies are urgently required.
منابع مشابه
Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...
متن کاملAssessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کاملRadiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma
Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...
متن کامل3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملOut-of-field photon dosimetry study between 3-D conformal and intensity modulated radiation therapy in the management of prostate cancer
Background: The present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (TPS), Oncentra, for three-dimensional conformal radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment techniques from Elekta Synergy medical linear accelerator. Materials and Methods: Accuracy of individual out-of-field dose components was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of radiation oncology, biology, physics
دوره 99 5 شماره
صفحات -
تاریخ انتشار 2017