Modelling light distributions of homogeneous versus discrete absorbers in light irradiated turbid media.

نویسندگان

  • W Verkruysse
  • G W Lucassen
  • J F de Boer
  • D J Smithies
  • J S Nelson
  • M J van Gemert
چکیده

Laser treatment of port wine stains has often been modelled assuming that blood is distributed homogeneously over the dermal volume, instead of enclosed within discrete vessels. The purpose of this paper is to analyse the consequences of this assumption. Due to strong light absorption by blood, fluence rate near the centre of the vessel is much lower than at the periphery. Red blood cells near the centre of the vessel therefore absorb less light than those at the periphery. Effectively, when distributed homogeneously over the dermis, fewer red blood cells would produce the same absorption as the actual number of red blood cells distributed in discrete vessels. We quantified this effect by defining a correction factor for the effective absorbing blood volume of a single vessel. For a dermis with multiple vessels, we used this factor to define an effective homogeneous blood concentration. This was used in Monte Carlo computations of the fluence rate in a homogeneous skin model, and compared with fluence rate distributions using discrete blood vessels with equal dermal blood concentration. For realistic values of skin parameters the homogeneous model with corrected blood concentration accurately represents fluence rates in the model with discrete blood vessels. In conclusion, the correction procedure simplifies the calculation of fluence rate distributions in turbid media with discrete absorbers. This will allow future Monte Carlo computations of, for example, colour perception and optimization of vascular damage by laser treatment of port wine stain models with realistic vessel anatomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo simulation of an optical coherence tomography signal in homogeneous turbid media.

The Monte Carlo technique with angle biasing is used to simulate the optical coherence tomography (OCT) signal from homogeneous turbid media. The OCT signal is divided into two categories: one is from a target imaging layer in the medium (Class I); the other is from the rest of the medium (Class II). These two classes of signal are very different in their spatial distributions, angular distribu...

متن کامل

FullMonte: a framework for high-performance Monte Carlo simulation of light through turbid media with complex geometry

Emerging clinical applications including bioluminescence imaging require fast and accurate modelling of light propagation through turbid media with complex geometries. Monte Carlo simulations are widely recognized as the standard for high-quality modelling of light propagation in turbid media, albeit with high computational requirements. We present FullMonte: a flexible, extensible software fra...

متن کامل

Monte Carlo study of pathlength distribution of polarized light in turbid media.

Photon pathlength distributions as a function of the number of scattering events in cylindrical turbid samples are studied using a polarization-sensitive Monte Carlo model with linearly polarized light input. Sample scattering causes extensive depolarization, yielding a photon field comprised of polarized and depolarized sub-populations. It is found that the pathlength of polarization-preservin...

متن کامل

Internal refractive index changes affect light transport in tissue

This investigation explores the effect of index of refraction, as an optical property, on light transport through optically turbid media. We describe a model of light propagation that incorporates the influence of refractive index mismatch at boundaries within a domain. We measure light transmission through turbid cylindrical phantoms with different distributions of refractive index. These dist...

متن کامل

Propagation of polarized light in birefringent turbid media: time-resolved simulations.

A Monte Carlo model was used to analyze the propagation of polarized light in linearly birefringent turbid media, such as fibrous tissues. Linearly and circularly polarized light sources were used to demonstrate the change of polarizations in turbid media with different birefringent parameters. Videos of spatially distributed polarization states of light backscattered from or propagating in bir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 1997