Chemometric exploration of an amperometric biosensor array for fast determination of wastewater quality.
نویسندگان
چکیده
Four wastewater samples of different treatment qualities; untreated, alarm, alert and normal, from a Swedish chemi-thermo-mechanical pulp mill and pure water were investigated using an amperometric bio-electronic tongue in a batch cell. The aim was to explore enzymatically modified screen-printed amperometric sensors for the discrimination of wastewater quality and to counteract the inherent drift. Seven out of eight platinum electrodes on the array were modified with four different enzymes; tyrosinase, horseradish peroxidase, acetyl cholinesterase and butyryl cholinesterase. At a constant potential the current intensity on each sensor was measured for 200s, 100s before injection and 100s after injection of the sample. The dynamic biosensor response curves from the eight sensors were used for principal component analysis (PCA). A simple baseline and sensitivity correction equivalent to multiplicative drift correction (MDC), using steady state intensities of reference sample (catechol) recordings, was employed. A clear pattern emerged in perfect agreement with prior knowledge of the samples explaining 97% of the variation in the data by two principal components (PCs). The first PC described the treatment quality of the samples and the second PC described the difference between treated and untreated samples. Horseradish peroxidase and pure platinum sensors were found to be the determinant sensors, while the rest did not contribute much to the discrimination. The wastewater samples were characterized by the chemical oxygen demand (COD), biological oxygen demand (BOD), total organic carbon (TOC), inhibition of nitrification, inhibition of respiration and toxicity towards Vibrio fischeri using Microtox, the freshwater alga Pseudokirchneriella subcapita and the freshwater crustacean Daphnia magna.
منابع مشابه
Bod Sensor for Wastewater Analysis - Design and Calibration Methods
Water quality monitoring is an important aspect of water management concerning to the pollution control. The removal of biodegradable organic substances is a very important aspect of evaluation the treatment efficiency in a wastewater treatment plant (WWTP). The amount of oxygen consumed by microorganisms to oxidise organic substances is characterised by biochemical oxygen demand (BOD), a widel...
متن کاملDetection of Waterborne and Airborne Formaldehyde: From Amperometric Chemosensing to a Visual Biosensor Based on Alcohol Oxidase
A laboratory prototype of a microcomputer-based analyzer was developed for quantitative determination of formaldehyde in liquid samples, based on catalytic chemosensing elements. It was shown that selectivity for the target analyte could be increased by modulating the working electrode potential. Analytical parameters of three variants of the amperometric analyzer that differed in the chemical ...
متن کاملDNA Biosensor for Determination of 5-Fluorouracil based on Gold Electrode Modified with Au and Polyaniline Nanoparticles and FFT Square Wave Voltammetry
In the present study, a new biosensor for 5-Fluorouracil was described using modified goldelectrode and Fast Fourier transform square wave voltammetry (FFT SWV). Calf thymus DNAimmobilization was on a gold electrode decorated with polyaniline and gold nanoparticles. Theelectrochemical characteristics of the electrodes were investigated by cyclic voltammetry, andelectroch...
متن کاملAMPEROMETRIC MICROBIOSENSOR FOR THE DETERMINATION OF CHOLINE
The construction and performance of an amperometric microbiosensor for the determination of choline chloride by immobilizing choline oxidase on a cellulose acetate membrane are described. The procedure of choline determination involved the electrochemical detection of enzymatically generated hydrogen peroxide. This microsensor has a linear response between 0.038-0.1 mM choline chloride. The...
متن کاملComparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission
Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biosensors & bioelectronics
دوره 21 4 شماره
صفحات -
تاریخ انتشار 2005