Comparison of five portable peak flow meters

نویسندگان

  • Glaucia Nency Takara
  • Gualberto Ruas
  • Bruna Varanda Pessoa
  • Luciana Kawakami Jamami
  • Valéria Amorim Pires Di Lorenzo
  • Mauricio Jamami
چکیده

OBJECTIVE To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05), Spearman's correlation test and Bland-Altman's agreement test. RESULTS The median and interquartile ranges for the spirometric values and the Air Zone, Assess, Galemed, Personal Best and Vitalograph meters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (p<0.001) and Galemed (p<0.01) meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Portable peak flow meters: physical characteristics, influence of temperature, altitude, and humidity.

Little is known about the linearity of portable peak flow meters, or about physical gas factors affecting peak expiratory flow (PEF) readings. We therefore tested five portable peak flow meters of three types in an altitude chamber (sea level to 5,500 m) and in a climate chamber at sea level (7-37 degrees C) to determine the influence of the physical conditions of the gas on the reading of the ...

متن کامل

Peak expiratory flow: conclusions and recommendations of a Working Party of the European Respiratory Society.

The use of peak flow meters has been widely adopted for monitoring patients with asthma. The Working Party of the European Respiratory Society (ERS) has solely addressed technical and physiological issues relating to peak expiratory flow (PEF) (flow describes the rate of change of volume (volume rate), so that flow rate is equivalent to volume acceleration. Hence, PEF should be used in preferen...

متن کامل

Eleven peak flow meters: a clinical evaluation.

Peak flow meters are essential tools in the management of asthma. Many types are on the market. A computer-driven piston pump is normally not available for evaluation of the various meters. Comparison with values from a pneumotachograph is an accepted way of testing peak flow meters. This study aims at comparing 11 peak flow meters, for accuracy and linearity. Seven adult peak flow meters were ...

متن کامل

[Peak expiratory flow rate in the management of cystic fibrosis]

OBJECTIVE: To verify the role of peak expiratory flow, measured through portable meters, as an alternative test to assess pulmonary disease in cystic fibrosis. METHODS: Forty-nine patients aged five to 19 years old in stable health condition and able to perform the peak expiratory flow maneuver were included. In the same visit, Shwachman-Kulczycki score was recorded. Linear regression was used ...

متن کامل

Bovine TB in badgers: a reappraisal of aetiology and pathogenesis.

I read with great interest the article of Miles et al. (1) about the performance of mini Wright peak flow meters after prolonged use. We performed a study (2) comparing the reliability of five new mini Wright peak flow meters before and after 10 000 compressed air impulses of about 4.50 1 min ’ flow, controlled by an electronically driven magnetic valve. There were no significant deviations of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 65  شماره 

صفحات  -

تاریخ انتشار 2010