Explant analysis of the Biomet Magnum/ReCap metal-on-metal hip joint

نویسندگان

  • S. C. Scholes
  • B. J. Hunt
  • V. M. Richardson
  • D. J. Langton
  • E. Smith
  • T. J. Joyce
چکیده

OBJECTIVES The high revision rates of the DePuy Articular Surface Replacement (ASR) and the DePuy ASR XL (the total hip arthroplasty (THA) version) have led to questions over the viability of metal-on-metal (MoM) hip joints. Some designs of MoM hip joint do, however, have reasonable mid-term performance when implanted in appropriate patients. Investigations into the reasons for implant failure are important to offer help with the choice of implants and direction for future implant designs. One way to assess the performance of explanted hip prostheses is to measure the wear (in terms of material loss) on the joint surfaces. METHODS In this study, a coordinate measuring machine (CMM) was used to measure the wear on five failed cementless Biomet Magnum/ReCap/ Taperloc large head MoM THAs, along with one Biomet ReCap resurfacing joint. Surface roughness measurements were also taken. The reason for revision of these implants was pain and/or adverse reaction to metal debris (ARMD) and/or elevated blood metal ion levels. RESULTS The mean wear rate of the articulating surfaces of the heads and acetabular components of all six joints tested was found to be 6.1 mm3/year (4.1 to 7.6). The mean wear rate of the femoral head tapers of the five THAs was 0.054 mm3/year (0.021 to 0.128) with a mean maximum wear depth of 5.7 µm (4.3 to 8.5). CONCLUSION Although the taper wear was relatively low, the wear from the articulating surfaces was sufficient to provide concern and was potentially large enough to have been the cause of failure of these joints. The authors believe that patients implanted with the ReCap system, whether the resurfacing prosthesis or the THA, should be closely monitored.Cite this article: S. C. Scholes, B. J. Hunt, V. M. Richardson, D. J. Langton, E. Smith, T. J. Joyce. Explant analysis of the Biomet Magnum/ReCap metal-on-metal hip joint. Bone Joint Res 2017;6:113-122. DOI: 10.1302/2046-3758.62.BJR-2016-0130.R2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hip resurfacing with the Biomet Hybrid ReCap-Magnum system: 7-year results.

The purpose of this study was to report our clinical outcome of a large series of metal-on-metal hip resurfacing arthroplasty (HRA) using the hybrid Biomet ReCap-Magnum system. This is a single-designer surgeon series with an average of 5 ± 1 years. Seven hundred forty consecutive hybrid HRAs were performed in 653 patients. Kaplan-Meier survivorship with any revision as an end point was 96.4% a...

متن کامل

Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty

BACKGROUND AND PURPOSE The clinical findings of adverse reaction to metal debris (ARMD) following large-diameter-head metal-on-metal total hip arthroplasty (LDH MoM THA) may include periarticular fluid collections, soft tissue masses, and gluteal muscle necrosis. The ReCap-M2a-Magnum LDH MoM THA was the most commonly used hip device at our institution from 2005 to 2012. We assessed the prevalen...

متن کامل

Incidence of adverse wear reactions in hip resurfacing arthroplasty: a single surgeon series of 2,600 cases.

A single surgeon performed 2,559 metal-on-metal hip resurfacing arthroplasties in 
2,109 patients. The Corin Cormet 2000 (393 cases) and Biomet Recap implants (2,166 cases) were used in our series. In this study, the adverse wear failure (AWF) rate was 0.27%. At 10 years postoperatively, our Kaplan-Meier cumulative revision rate for AWF was 1% for all patients, 0.2% for men, 2.6% for women, and...

متن کامل

Few Adverse Reactions to Metal on Metal Articulation in Total Hip Arthroplasty in a Review Study on 358 Consecutive Cases with 1 to 5 Years Follow-Up

The aim of the present study was to determine the frequency of adverse reaction to metal on metal total hip arthroplasty using a M2a-38 articulation and a Magnum articulation, (Biomet Warsaw, Indiana).All patients who had received a Metal on Metal bearing prosthesis, in two centres in Copenhagen, were asked to complete a questionnaire about groin pain. Patients with self-reported groin pain, 68...

متن کامل

Hip resurfacing in a district general hospital: 6-year clinical results using the ReCap hip resurfacing system

BACKGROUND The purpose of our study was to prospectively report the clinical results of 280 consecutive hips (240 patients) who received a ReCap Hip Resurfacing System implant (Biomet Inc., Warsaw, USA) in a single district general hospital. Literature reports a large variation in clinical results between different resurfacing designs and published results using this particular design are scarc...

متن کامل