Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study.

نویسندگان

  • T Apivatthakakul
  • J Phaliphot
  • S Leuvitoonvechkit
چکیده

BACKGROUND A percutaneous cerclage wiring technique has been developed to reduce iatrogenic soft tissue and vascular disruption associated with classic cerclage fixation. OBJECTIVES The purpose of this study was to evaluate the extent of femoral vascular disruption resulting iatrogenically from the application of two percutaneous cerclage wire loops. METHODS Pairs of cerlage wire loops were percutaneously inserted on 18 fresh cadaveric femurs. The position of the wire loops varied. The wire loops were either inserted 10 and 15cm, 10 and 20cm, or 15 and 20cm distal to the tip of the greater trochanter. Each study group had 6 cadavers. Contralateral femurs without cerclage wiring were used as controls. Liquid contrast-gelatin was injected into the common femoral artery. Using axial and 3D CT scan images the superficial femoral artery (SFA), deep femoral artery (DFA), perforating arteries and their anastomotic patterns as well as endosteal perfusion were identified and their patency was graded. RESULTS Percutaneous cerclage wiring did not disrupt femoral endosteal blood supply and maintained the integrity of all of the superficial femoral arteries. Four specimens demonstrated maintenance of all 4 perforators, 11 showed disruption of 1 perforator, and 3 showed disruption of 2 perforators. One deep femoral artery was disrupted after its first perforator branched off; however, perfusion was maintained by fill from an alternative anastamosis. There was no significant difference between disruption of deep femoral arteries and perforating arteries (P=1.000), location of wiring (P=0.905) or spacing between wire loops (P=1.000). CONCLUSION Percutaneous cerclage wiring resulted in minimal disruption of the femoral blood supply. When partial disruption occurred the SFA, DFA, and their associated perforators compensated to maintain femoral perfusion through their anastomoses. The location of the cerclage wire and the distance between the wire loops in the proximal femur showed no significant difference in the rate of iatrogenic perforator injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Separate Vertical Wiring for the Fixation of Comminuted Fractures of the Inferior Pole of the Patella

PURPOSE Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). MATERIALS AND METHODS Multiple oste...

متن کامل

Percutaneous cerclage wiring for the surgical treatment of displaced patella fractures

The patella plays an important role in the knee joint extension, and a patella fracture requires surgical treatment when it is accompanied by displacement of bone fragments and a joint surface gap. In patella fractures, there is disruption of the soft tissue structures that support the knee extension mechanism. We use a method of percutaneous cerclage wiring to fix the patella and include the p...

متن کامل

Internal fixation for fractures of the patella. A comparison of two methods.

Cadaveric experiments in 10 knees were used to study the strength of two methods of internal fixation for a fractured patella. A modified AO tension band technique was compared with the combination of cerclage wiring and a tension band used at Pyrford. The repairs were stressed to failure; the combination of cerclage and tension band wiring proved to be significantly stronger and is recommended.

متن کامل

Cerclage Wiring as an Adjunct for the Treatment of Femur Fractures: Series of 11 Cases

Introduction Cerclage wiring has been used in the past for osteosynthesis of femoral fractures. However, the technique went into disrepute as extensive soft tissue dissection, and periosteal stripping increased the risk of bone necrosis and delayed union. Advent of new instrumentation and minimally invasive technique has significantly reduced these complications. In spite of the limited indicat...

متن کامل

The use of cerclage wire for surgical repair of unilateral rostral mandibular fracture in horses

Fractures of the rostral mandible in horses are the most common type of jaw fractures. The present study was performed for stabilization of rostral mandibular fracture with cerclage wire. In a retrospective case series, six client-owned horses with unilateral mandibular fractures were admitted to our clinic and suffered from a major gingival wound at rostral part of mandible. Rostral mandibular...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Injury

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2013